PubMed HealthSearch

PubMed · 6419587

More efficient system for preparing total parenteral nutrient solutions.

Abstract

An improved system for preparing total parenteral nutrient (TPN) solutions is described. The new system uses a personal computer, a three-station volumetric pump, and empty polyvinyl chloride (PVC) containers. The computer's order-entry screen facilitates data entry by displaying a format similar to the physician's order sheet. After calculating the volumes of i.v. solutions and additives and the total cost of the TPN solution, the computer prints labels containing this information. Using the volumetric pump, the required volumes of crystalline amino acids, dextrose injection, and sterile water for injection are added simultaneously to either one-liter or three-liter PVC containers. Each bag contains the patient's entire daily TPN requirements. Approximately 30 liters of TPN solution are prepared daily by specially trained technicians in a centralized i.v. room. Compared with the previous method of preparing TPN solutions using evacuated one-liter glass bottles, the average time required to prepare and determine the cost of each patient's TPN solutions has decreased from 35 to 21 minutes daily. Total savings resulting from reduced materials and labor costs is approximately $28,240 annually. The new system for preparing TPN solutions is efficient and cost effective.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Condella, R J Baptista, R E Griffin. 1983. More efficient system for preparing total parenteral nutrient solutions.. https://pubmed.ncbi.nlm.nih.gov/6419587/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A correction factor for bridging compaction simulator and different roller compactors.

Roller compaction (RC) is an important dry granulation technique. Since pilot and commercial scale roller compactors, which operate continuously on a large scale, usually require kilograms of material per run, formulation and process development directly on such roller compactors is not practical. In contrast, a compaction simulator (CS) can produce ribblets, also known as "slugs", using only a few grams of material with sinusoidal displacement profile replicating the motion of a specific point on the roll surface. Thus, it is possible to develop RC formulation and process in laboratory using a CS-based material-sparing approach. However, because of the inherently different configurations for applying pressure between die compression and roll compression, translating uniaxial pressure from CS experiments to roll pressure during RC is often unreliable, leading to significant uncertainties in the critical quality attributes of ribbons, such as ribbon solid fraction (or porosity) and mechanical strength. The objective of this study was to identify a correction factor (Kp = uniaxial die compression pressure/roll pressure), by correlating the compressibility profiles from CS and a roller compactor of interest, to enable more reliable process translation from CS to roller compactor. In this study, a Kp value of 0.5 was determined for Alexanderwerk WP120 and validated for Gerteis Mini-Pactor and Bepex Pharmapactor. This value may serve as a starting point for translating the optimal compaction pressure identified based on CS investigation to common roller compactors, requiring only minor adjustments to attain optimal RC process parameters (i.e., roll force and roll gap) for a chosen roller compactor.

Drug Compounding

Design and evaluation of a sterile compounding facility.

The design and evaluation of a sterile compounding center for a large community teaching hospital are described. The new sterile products area was redesigned to improve efficiency by minimizing staff travel and to incorporate recommendations of the ASHP Technical Assistance Bulletin on Quality Assurance for Pharmacy-prepared Sterile Products. The design approach combined strategic planning with master facilities planning. The process began with a systems analysis, followed by the development of a functional program (a comprehensive list of design specifications). Travel studies were performed before and after renovation to determine gains in efficiency; technician travel decreased 29% and pharmacist travel, 42%. The new facility design met the specifications in the functional program and appeared to comply with all recommendations in the ASHP document for all risk levels of preparations.

Drug Compounding