[Progress in endoprosthesis via computed tomography?].

Abstract

A new procedure for the manufacture of endoprostheses with the aid of computer tomography is described. This modern radiological technique has not only revolutionised many diagnostic problems, but will also affect treatment intimately.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Aldinger, B Kurtz. 1984. [Progress in endoprosthesis via computed tomography?].. https://doi.org/10.1055/s-2008-1053180

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correlating subjective and objective descriptors of ultra high molecular weight wear particles from total joint prostheses.

A total of 750 images of individual ultra-high molecular weight polyethylene (UHMWPE) particles isolated from periprosthetic failed hip, knee, and shoulder arthroplasties were extracted from archival scanning electron micrographs. Particle size and morphology was subsequently analyzed using computerized image analysis software utilizing five descriptors found in ASTM F1877-98, a standard for quantitative description of wear debris. An online survey application was developed to display particle images, and allowed ten respondents to classify particle morphologies according to commonly used terminology as fibers, flakes, or granules. Particles were categorized based on a simple majority of responses. All descriptors were evaluated using a one-way ANOVA and Tukey-Kramer test for all-pairs comparison among each class of particles. A logistic regression model using half of the particles included in the survey was then used to develop a mathematical scheme to predict whether a given particle should be classified as a fiber, flake, or granule based on its quantitative measurements. The validity of the model was then assessed using the other half of the survey particles and compared with human responses. Comparison of the quantitative measurements of isolated particles showed that the morphologies of each particle type classified by respondents were statistically different from one another (p<0.05). The average agreement between mathematical prediction and human respondents was 83.5% (standard error 0.16%). These data suggest that computerized descriptors can be feasibly correlated with subjective terminology, thus providing a basis for a common vocabulary for particle description which can be translated into quantitative dimensions.

Joint Prosthesis↗

[Oxidation of ultra high molecular weight polyethylene as a result of sterilization].

PURPOSE OF THE STUDY: To improve (UHMWPE) Ultra High Molecular Weight Polyethylene quality for use in arthroplastic components, sterilization related oxidative changes were investigated in raw and manufactured material. MATERIAL: To evaluate sterilization related effects, 15 x 15 mm samples of UHMWPE were taken from a defined area of raw manufactured UHMWPE plates. The raw manufactured plates were produced using the compression molding method. For sterilization, gamma irradiation with and without air, ETO-sterilization and autoclave sterilization were performed. METHODS: Infrared spectroscopy was used to detect oxidation damage of the implant in superficial and deep layers of the material. RESULTS: Gamma sterilization on air showed 40% more oxidation compared with air-free sterilization. The superficial oxidation on air was 0.33 and showed the lowest value without air on argon with 0.155. Using ethylenoxide sterilization, no great changes in superficial oxidation (0.229) were observed; the smallest change (0.07) was observed at a depth of 2.79 mm. Autoclave sterilization caused the greatest superficial oxidation with 0.622 but low oxidation at 0.094 mm depth. In all samples, further oxidation and ongoing crystallinity was seen with increasing storage time. CONCLUSION: Ethylenoxide sterilization should be recommended for UHMWPE since oxidative changes is lowest. Gamma sterilization can only be recommended without air and at low doses.

Joint Prosthesis↗

A prognosis for ultra high molecular weight polyethylene.

Ultra high molecular weight polyethylene (UHMPWE) is now the material of choice for total joint replacement prostheses, in combination with a metal surface against which the polymer articulates. As this material has now been in use in this application for approximately three decades and other limiting factors (e.g. loosening of the prosthesis) have been improved upon, it is appropriate to attempt a long-term prognosis.

Joint Prosthesis↗