Eye-controlled communication aids.

Abstract

Two types of eye-controlled aids for two categories of nonvocal patients with paralysis are described: one based on the use of an eye switch by the partially defect eye for the selection of letters and the other based on position recording of the intact eye during its fixation on the desired letter. The eye recording device for both aids was designed to be drift-free and insensitive to ambient light and heat sources, using an infrared limbus-pupil-reflection method. Different selection procedures with and without visual feedback were analyzed. Feedback reduced the number of selection errors significantly. Maximum selection speeds obtained with the eye switch controlled aids and with the eye position controlled aid were 15, 30, and 105 letters/min, respectively. Eye switch-controlled aids have been used in rehabilitation. Possible application of the aids and plans are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J H ten Kate, E E Frietman, F J Stoel, W Willems. 1980. Eye-controlled communication aids.. https://pubmed.ncbi.nlm.nih.gov/6450877/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Linear servo-controlled pressure generator for forced oscillation measurements.

In respiratory input impedance measurements, the low-frequency range contains important clinical and physiological information. However, the patient's spontaneous ventilation can contaminate the data in this range, leading to unreliable results. Unbiased estimators are a good alternative to overcome this problem, provided that the generator is considered linear. This condition is not fulfilled by most existing generators as they are based on loudspeakers, which have strong nonlinearities. The present work aims to contribute to the solution of this problem, and describes a pressure generator that minimises the nonlinearities by an optical sensor placed in a position feedback loop. The static evaluation shows a high linearity for the optical system. The well known frequency response of pressure transducers is used in the dynamic evaluation of the instrument. The analysis of the generator shows that the use of position feedback improved the frequency response. The total harmonic distortion (THD) measurement shows that closed loop resulted in an effective decrease in the nonlinearities. The reduction of THD achieved by the servo-controlled generator can contribute to the practical implementation of the unbiased estimators, increasing the reliability of the impedance data, especially in the low-frequency range. This system is compared with conventional generators and with another servo-controlled system.

Biomedical Engineering