External defibrillation: new technologies.

Abstract

Recent technological advances have enhanced our ability to diagnose and treat ventricular fibrillation (VF). Self-adhesive electrode pads for external defibrillation are as effective as standard hand-held paddle electrodes, and have substantial advantages for monitoring during transportation and in the emergency department/intensive care unit/critical care unit. These electrode pads work equally well whether placed in apex-anterior or apex-posterior positions. Preapplication in calm, prearrest circumstances assures accurate placement and enhances shock success. Transthoracic impedance is a critical determinant of the success of low-energy shocks. Prediction of transthoracic impedance in advance of the first shock is now feasible. First-shock energy can then be based on impedance, and inappropriate low energies for high-impedance patients may be avoided. Automatic external defibrillation by minimally trained rescuers extends our ability to treat out-of-hospital ventricular fibrillation. A vertical defibrillation pathway, using the tongue as one electrode site, allows rapid, automated detection of VF. Animal defibrillation studies and preliminary human studies (during elective cardioversion) have demonstrated the efficacy of the pathway and defined the impedance and energy requirements. Clinical trials of the device for out-of-hospital defibrillation are now in progress.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Kerber. 1984. External defibrillation: new technologies.. https://doi.org/10.1016/s0196-0644(84)80440-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An advanced signal processing technique for impedance cardiography.

A new design using the latest technique in signal processing, the time-frequency analysis method, was developed to process impedance cardiography signals. This technique, when used to determine the relevant calculation parameters, was found to be more accurate than conventional methods. It was shown to be advantageous in reducing ventilation artifacts and motion noise, resulting in greater accuracy. Its cardiac output values had a much better correlation coefficient when compared in the clinical setting to the standard thermodilution technique than did the values from conventional impedance cardiography devices.

Cardiography, Impedance

Examination of impedance cardiography properties--FEM model studies.

A FEM has been used to examine influence of tissues' conductivities and electrodes' array configurations on the results obtained by Impedance Cardiography. A Geselowitz's relationship has been applied to estimate partial contributions from each region of thorax. The obtained results have indicated the strong dependence of ICG signal on factors mentioned above. It seems that additional measurements and more advanced ICG waveform processing must be done to minimise errors in estimating parameters of mechanical work of heart by means of ICG.

Cardiography, Impedance