PubMed HealthSearch

PubMed · 6495245

Temperature corrections in routine spirometry.

Abstract

Forced expiratory volume (FEV1) and forced vital capacity (FVC) were measured in nine normal subjects with three Vitalograph and three rolling seal spirometers at three different ambient temperatures (4 degrees C, 22 degrees C, 32 degrees C). When the results obtained with the rolling seal spirometer were converted to BTPS the agreement between measurements in the three environments improved, but when the Vitalograph measurements obtained in the hot and cold rooms were converted an error of up to 13% was introduced. The error was similar whether ambient or spirometer temperatures were used to make the conversion. In an attempt to explain the behaviour of the Vitalograph spirometers the compliance of their bellows was measured at the three temperatures. It was higher at the higher temperature (32 degrees C) and lower at the lower temperature (4 degrees C) than at the normal room temperature. These changes in instrument compliance could account for the differences in measured values between the two types of spirometer. It is concluded that the ATPS-BTPS conversion is valid and necessary for measurements made with rolling seal spirometers, but can cause substantial error if it is used for Vitalograph measurements made under conditions other than normal room temperature.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Cramer, A Peacock, D Denison. 1984. Temperature corrections in routine spirometry.. https://doi.org/10.1136/thx.39.10.771

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The role of three dimensional functional lung imaging in radiation treatment planning: the functional dose-volume histogram.

PURPOSE: During thoracic irradiation (XRT), treatment fields are usually designed to minimize the volume of nontumor-containing lung included. Generally, functional heterogeneities within the lung are not considered. The three dimensional (3D) functional information provided by single photon emission computed tomography (SPECT) lung perfusion scans might be useful in designing beams that minimize incidental irradiation of functioning lung tissue. We herein review the pretreatment SPECT scans in 86 patients (56 with lung cancer) to determine which are likely to benefit from this technology. METHODS AND MATERIALS: Prior to thoracic XRT, SPECT lung perfusion scans were obtained following the intravenous injection of approximately 4 mCi of 99mcTc-labeled macro-aggregated albumin. The presence of areas of decreased perfusion, their location relative to the tumor, and the potential clinical usefulness of their recognition, were scored. Patients were grouped and compared (two-tailed chi-square) based on clinical factors. Conventional dose-volume histograms (DVHs) (DVFHs) are calculated based on the dose distribution throughout the computed tomography (CT)-defined lung and SPECT-defined perfused lung, respectively. RESULTS: Among 56 lung cancer patients, decreases in perfusion were observed at the tumor, adjacent to the tumor, and separate from the tumor in 94%, 74%, and 42% of patients, respectively. Perfusion defects adjacent to the tumor were often large with centrally placed tumors. Hypoperfusion in regions separate from the tumor were statistically most common in patients with relatively poor pulmonary function and chronic obstructive pulmonary disease (COPD). Considering all SPECT defects adjacent to and separate from the tumor, corresponding CT abnormalities were seen in only approximately 50% and 20% of patients, respectively, and were generally not as impressive. Following XRT, hypoperfusion at and separate from the tumor persisted, while defects adjacent to the tumor improved in several patients. In four patients who achieved a complete response scored by CT with chemotherapy prior to XRT, persistent hypoperfusion was present at and adjacent to the tumor site in three. Among 30 patients with cancers not arising in the lung (14 breast, 12 lymphoma, 4 others), perfusion defects were seen in only 4 (2 adjacent and 2 apart). Recognition of decreases in perfusion mainly impacted on treatment planning for a few patients with poor pulmonary function and limited target volumes. DVFHs have been useful in beam selection for patients with marked perfusion heterogeneities. CONCLUSIONS: Lung perfusion scans provide functional information not provided by CT scans that can be useful in designing radiation treatment beams that minimize incidental irradiation of the function regions of the lung. This approach appears to be most helpful in patients with gross intrathoracic lung cancer, especially those with small targets and relatively poor pulmonary function. One limitation of this approach is that some of the defects adjacent to the tumor site reperfuse following treatment, indicating that these scans identify perfusion rather than potential perfusion. Three dimensional functional data can be used to generate DVFHs that may be more predictive of the physiological consequences of the radiation than conventional DVHs. Additional work is currently underway to test this hypothesis.

Forced Expiratory Volume

Ventilation and perfusion lung imaging--which nebulizer?

Three commercially available 99Tcm-diethylenetriamine pentaacetate (99Tcm-DTPA) aerosol delivery nebulizers for lung ventilation imaging were investigated. Two were air-jet systems, 'Optimist' (Medicaid) and 'Microcirrus' (Amersham), and one was an ultrasonic device (Europlus). Altogether, 112 consecutive patients were scanned, 37 using the Optimist, 40 using the Microcirrus and 35 the Europlus. The age mix, FEV1, FVC and PEFR measurements of the patients in each group were similar. Each contained a proportion of patients with poor respiratory function, with PEFR rates ranging from 30 to 582 l min-1 for patients studied with all systems. Ease of use, image quality and cost were evaluated as well as radioactive and microbiological contamination. The Optimist system gave the best combination of image quality and cost, and was associated with the lowest level of radioactive contamination. It also proved the most popular. Airborne contamination for all nebulizers was lower than previously reported and was largely dependent on patient compliance. With poorly compliant patients, the contamination levels are sufficient to warrant an extraction device. There was no evidence of bacterial contamination of the nebulizers or tubing on repeated use over 5 days.

Forced Expiratory Volume