PubMed HealthSearch

PubMed · 6507965

Ventricular interaction with the loading system.

Abstract

The purpose of this investigation was to develop a theoretical framework to predict stroke volume (and therefore cardiac output) when the ventricle is coupled with the arterial impedance. The ultimate objective is to arrive at an analytical description of cardiac output in the closed hydraulic loop of the entire circulatory system on the basis of the properties of the major system components. We developed the framework of analysis of ventriculo-arterial coupling by characterizing both the ventricle and arterial system in terms of the end-systolic pressure vs. stroke volume (Pes-SV) relationships. This approach, motivated by the load-insensitivity of ventricular end-systolic pressure-volume relationship (ESPVR), yielded stroke volume as the intersection between the ventricular Pes-SV relationship and arterial Pes-SV relationship. The theoretical outcome was validated by comparing the stroke volume predicted as a result of interaction between a given ventricular ESPVR and a set of arterial impedances against those SVs actually measured by imposing the same arterial impedance on the isolated canine ventricles. Furthermore, because of the mathematical simplicity of this approach, it enabled us to describe cardiac output in the closed circulatory loop with a small set of analytical equations. We conclude that the proposed framework is useful in analyzing the ventriculo-arterial coupling and various mechanisms which affect cardiac output in the closed circulatory loop.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Sunagawa, K Sagawa, W L Maughan. 1984. Ventricular interaction with the loading system.. https://doi.org/10.1007/bf02584229

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Magnetic resonance tomographic angiography: diagnostic value in trigeminal neuralgia.

A combination of MRI, MR angiography and MR tomographic angiography (MRTA) was used to study the relationship of the root exit zone of the trigeminal nerve to surrounding vascular structures in seven patients with trigeminal neuralgia (TN) and ten patients with no evidence at a lesion in this region. MRTA is the technique for showing the relationship between vessels, cranial nerves and brain stem. MRTA clearly demonstrated the presence of a vessel at the root exit zone of the trigeminal nerve in all patients with TN. In the ten other patients, examination of 20 trigeminal nerves revealed that only one nerve (5%) was in contact with a vessel at the root exit zone. This study supports vascular compression of trigeminal nerves as a cause of TN, and demonstrates the value of MRTA as noninvasive technique for demonstrating compression.

Arteries

Intravascular ultrasound image subtraction: a contrast enhancing technique to facilitate automatic three-dimensional visualization of the arterial lumen.

At 30 MHz, the intravascular ultrasound backscatter of blood confounds the discrimination of the lumen from the arterial wall. This study validates a subtraction method which creates a still-frame image with a sharp demarcation of the lumen. The method involves subtraction of consecutive images and 2D ensemble averaging of the absolute pixel values. Subtraction exploits the dynamic properties of flowing red blood cells. Three phantom arteries were used, with erythrocytes in their lumens and wall. For this reason, it was not possible, in one single original image, to discriminate the blood in the lumen from the phantom wall. Based on 26 consecutive original images, in the mean subtraction image contrast between lumen and phantom wall grey values increased eightfold from 10.9 (5.3-19.2) (mean and range) in the original image to 87.7 (73.6-107.0) (P < 0.001). A sufficiently large contrast increase to allow automatic segmentation was obtained by using five original images (0.3-s acquisition time) for any single mean subtraction image. Low blood flow velocities (down to 0.5 cm/s) did not alter this result. Automatic segmentation of the lumen allowed fast 3D reconstruction of the lumen in all three phantom arteries. In phantom arteries, the intravascular ultrasound image subtraction technique improved contrast between lumen and wall which enabled automated lumen segmentation and fast 3D visualization of both the lumen and defects in the wall.

Arteries