PubMed HealthSearch

PubMed · 6527253

Dissolution at porous interfaces VI: Multiple pore systems.

Abstract

With the aid of rapidly dissolving sodium chloride particles, cubic pores were made in the surface of a theophylline tablet. The influence of the pores on the dissolution rate of the surface was investigated in a rotating disk apparatus. Like the drilled pores used in earlier studies, downstream on the surface they caused a turbulent flow regimen with the development of a trough due to enhanced erosion. The phenomenon of a critical pore diameter, discovered with single, drilled pores, seems to be applicable to the cubic pores investigated in this study, although a higher degree of surface coverage with pores caused complications, probably due to particles bordering one another and forming larger pores. The behavior of the porous surfaces at different rotation speeds was studied. Due to the presence of pores the laminar character of the boundary layer flow changes to turbulent, which induces locally an increased dissolution flux in the wake of a pore.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Grijseels, D J Crommelin, C J De Blaey. 1984. Dissolution at porous interfaces VI: Multiple pore systems.. https://doi.org/10.1002/jps.2600731228

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Particle size and content uniformity.

The requirements of the USP Content Uniformity test are translated into physical and mathematical parameters. Assuming spherical particle sizes with a log normal distribution, the mean particle size and particle size distribution required to insure a high probability of passing the content uniformity test are calculated. On the basis of these calculations it is shown that satisfactory tablets of low doses cannot be manufactured from a drug that does not meet certain particle size distribution specifications. It is recommended that particle size specifications for low dose drugs include a requirement for a limit to size distribution.

Particle Size

Rapid detection and size determination of PuO2 particles using a charged-particle imaging video monitor system.

A charged-particle imaging video monitor system was constructed and applied to video imaging of the position profile of PuO2 particles on filter paper. The imaging video monitor system consists of a detector head, a silicon intensifier target (SIT) camera, a video frame memory, and a personal computer. The system can display the distribution image of PuO2 particles becoming gradually clearer on a video monitor. The integrated image that is transferred to the computer is analyzed quantitatively for the radioactivity of each PuO2 particle deposited on the filter paper. The system can not only rapidly distinguish PuO2 particle contamination from Rn daughter products, but can also determine the size distribution of the PuO2 particles.

Particle Size

[Study of talc for pharmaceutical use. Trials of pharmacopoeias].

A study has been carried out on the possible pharmaceutical use of spanish talcs following the normalized assays of the main european pharmacopoeia and other quantitative methods. Only the talc nr3, not processed, meets all the assays of pharmacopoeia. The samples 2 and 4 (crushed) exceed the highest tolerated content in chlorides. The talc 1 (also crushed) only meets the loss on drying. The measures of some of these assays by using quantitative methods lead to more correct results and even sometimes in opposition with those obtained by pharmacopoeia methods. The particle size estimated by shifting and sedimentation shows that the crushed talcs are silty, whereas the only talc not processed is sandy. Considering the medium sizes estimated by scanning microscopy, it can be said that the pulverization of the talcs 1, 2 and 4 is characteristic of a micronization.

Particle Size