Description of analytical problems arising from elevated serum solids.

Abstract

There has always been a problem with the collection of data and interpretation of the results obtained from any biological fluid in which the solids content was increased to a great extent. Of these solids, the triglycerides of the lipids may cause a plasma (serum) to vary in appearance from opalescent to milky. This condition of the specimen and the concomitant turbidity upon its addition to reagents creates the well-documented optical aberrations of spectrophotometric measurements. In addition, the lipids, in conjunction with the proteins, can act as diluents when they are elevated, thereby decreasing what might be termed the residual true plasma volume. Thus the water content of an aliquot sampled for a particular analytical procedure is diminished, and by that means a situation is created in which a short sample is drawn. This dilution effect by the solids results in a lowering of the assay values obtained for the measured constituents of such a serum sample. An associated phenomenon of high concentrations of solids, especially proteins, is the increase in viscosity of a specimen, a condition that also causes an error of short sampling when certain peristaltic pumping devices are used. This review considers several aspects of problems encountered when dealing with a number of circumstances that are critical to the measurement of analytes in severely hyperlipemic and/or hyperproteinemic specimens. These include the problems of short sampling; the potential amelioration of the problem by corrective mathematics, extraction of the lipids, or ultracentrifugation of the true plasma from the lipids; the important need to include most analytes into our considerations; the difference in reference base values for the calculation of concentrations of lipids of serum versus other analytes; the concept of the use of ratios when the reference base values differ, numerator analyte from denominator analyte; and the problems of using serum blanks when necessary corrective action for the solids volume is neglected. Thus, in the final analysis, problems with underestimated volumes of samples used for many spectrophotometric determinations are considered here along with the other difficulties encountered when the need to measure analytes in serums with extremely high solids content presents.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M W McGowan, J D Artiss, B Zak. 1984-11-01. Description of analytical problems arising from elevated serum solids.. https://doi.org/10.1016/0003-2697(84)90460-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of Delta9-tetrahydrocannabinolic acid A in human urine and blood serum by LC-MS/MS.

Delta9-tetrahydrocannabinolic acid A (Delta9-THCA-A) is the precursor of Delta9-tetrahydrocannabinol (Delta9-THC) in hemp plants. During smoking, the non-psychoactive Delta9-THCA-A is converted to Delta9-THC, the main psychoactive component of marihuana and hashish. Although the decarboxylation of Delta9-THCA-A to Delta9-THC was assumed to be complete--which means that no Delta9-THCA-A should be detectable in urine and blood serum of cannabis consumers--we found Delta9-THCA-A in the urine and blood serum samples collected from police controls of drivers suspected for driving under the influence of drugs (DUID). For LC-MS/MS analysis, urine and blood serum samples were prepared by solid-phase extraction. Analysis was performed with a phenylhexyl column using gradient elution with acetonitrile. For detection of Delta9-THCA-A, the mass spectrometer (MS) (SCIEX API 365 triple-quadrupole MS with TurboIonSpray source) was operated in the multiple reaction monitoring (MRM) mode using the following transitions: m/z357 --> 313, m/z357 --> 245 and m/z357 --> 191. Delta9-THCA-A could be detected in the urine and blood serum samples of several cannabis consumers in concentrations of up to 10.8 ng/ml in urine and 14.8 ng/ml in serum. The concentration of Delta9-THCA-A was below the Delta9-THC concentration in most serum samples, resulting in molar ratios of Delta9-THCA-A/Delta9-THC of approximately 5.0-18.6%. Only in one case, where a short elapsed time between the last intake and blood sampling is assumed, the molar ratio was 18.6% in the serum. This indicates differences in elimination kinetics, which need to be investigated in detail.

Blood Chemical Analysis↗