PubMed HealthSearch

PubMed · 6539980

Diffraction tomography using arbitrary transmitter and receiver surfaces.

Abstract

The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan beam) insonification. Special attention is devoted to cases where the measurement and source boundaries are either lines or circles. The theory and algorithms presented are shown to be readily extended to the case of three-dimensional objects.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A J Devaney, G Beylkin. 1984. Diffraction tomography using arbitrary transmitter and receiver surfaces.. https://doi.org/10.1177/016173468400600207

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Research and development in the blood bank: efforts of a hospital donor center to improve efficiency of in-line leukocyte reduction filters for automated plateletpheresis.

In-line leukocyte reduction filters (LRF) are available for use with an automated plateletpheresis (PPH) system. Initially, 62% of PPH units produced with such a filter (LRF6, N = 29) had postfiltration (POF) white blood cell (WBC) counts < 5 x 10(6), with a mean POF WBC of 42 x 10(6). In an attempt to decrease POF WBCs, PPH were rested 30 to 60 minutes before filtration with LRF6. A new, larger-volume LRF (LRF10) was also assessed for its efficiency of leukodepletion. A total of 625 PPH, 490 filtered with LRF6 and 135 with LRF10, were evaluated using prefiltration (PRF) and POF samples. Mean prefiltration WBC loads averaged 80 x 10(6) (range, 60-88 x 10(6)) using seven combinations of filters, collection software, and PRF rest periods. Ninety-three percent of PPH units rested prior to filtration with LRF6 (N = 237) had < 5 x 10(6) WBC POF, with a mean of 5 x 10(6) WBC POF. All PPH units filtered with LRF10 (N = 135), whether rested or not, had < 5 x 10(6) WBC POF, with a mean WBC count of 0.2 x 10(6) POF. Mean platelet (PLT) yields POF ranged from 3.1 to 3.4 x 10(11). A PRF rest decreased mean POF WBC counts in products filtered with LRF6. The LRF10 consistently produced PPH with < 5 x 10(6) WBC POF. Blood centers must thoroughly validate equipment utilized in the production of blood components.

Filtration

An effective LDL removal filter for the treatment of hyperlipidemia.

On-line membrane plasma fractionation techniques have made semiselective removal of pathological macromolecules practical. However, several problems such as cryogel formation exist when the procedure is performed at ambient temperature. Cryogel formation takes place when heparinized plasma is cooled below 35 degrees C and when it tends to occlude the pore structure of the secondary filter membrane resulting in a poor molecular cut off of the macromolecular filter. Thermofiltration is one of the on-line plasma fractionation techniques used when warming plasma from 37 to 42 degrees C to prevent cryogel formation. Thermofiltration enhanced the performance of the lipofilter (Kuraray 4A) and demonstrated better molecular cut off between low density lipoprotein (LDL) cholesterol and high density lipoprotein (HDL) cholesterol than double filtration plasmapheresis (DFPP). An improved lipofilter (Kuraray 5A) has been developed and has shown better molecular cut off between LDL cholesterol and HDL cholesterol than the 4A filter. However, cryogel formation still occurred even using the 5A filter during the DFPP procedure. Thermofiltration maintains the performance of the secondary filter by preventing cryogel formation. Further studies are required to evaluate the enhanced performance of the 5A filter by thermofiltration.

Filtration