PubMed Health⌕ Search

PubMed · 6540913

Diffraction tomography using beam waves: z-average reconstruction.

Abstract

This paper discusses the problem of diffraction tomography, when a general beam wave is used as the excitation and the three-dimensional structure of the object is considered. The special case of a zero-order beam wave with measurements of the average of the scattered field in the z direction is detailed. It is shown that in this case a reconstruction algorithm identical to the two-dimensional geometry yields a z-averaged tomogram of the inhomogeneity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Z Q Lu, M Kaveh, R K Mueller. 1984. Diffraction tomography using beam waves: z-average reconstruction.. https://doi.org/10.1177/016173468400600108

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Specific coil design for SENSE: a six-element cardiac array.

In sensitivity encoding (SENSE), the effects of inhomogeneous spatial sensitivity of surface coils are utilized for signal localization in addition to common Fourier encoding using magnetic field gradients. Unlike standard Fourier MRI, SENSE images exhibit an inhomogeneous noise distribution, which crucially depends on the geometrical sensitivity relations of the coils used. Thus, for optimum signal-to-noise-ratio (SNR) and noise homogeneity, specialized coil configurations are called for. In this article we study the implications of SENSE imaging for coil layout by means of simulations and imaging experiments in a phantom and in vivo. New, specific design principles are identified. For SENSE imaging, the elements of a coil array should be smaller than for common phased-array imaging. Furthermore, adjacent coil elements should not overlap. Based on the findings of initial investigations, a configuration of six coils was designed and built specifically for cardiac applications. The in vivo evaluation of this array showed a considerable SNR increase in SENSE images, as compared with a conventional array. Magn Reson Med 45:495-504, 2001.

Fourier Analysis↗

Fourier-transform EPR at high-field/high-frequency (3.4 T/95 GHz) using broadband stochastic microwave excitation.

Stochastic excitation with a full-width-half-maximum bandwidth of 250 MHz was used to perform Fourier-transform (FT) high-field/high-frequency electron paramagnetic resonance (EPR) at 3.4T/95 GHz (W-band). Thereby, the required microwave peak power is reduced by a factor of tau(p)/T1 as compared to equivalent pulsed FT EPR in which the spin system with spin-lattice relaxation time T1 is excited by a single microwave pulse of length tau(p). Stochastic EPR is particularly interesting under high-field/high-frequency conditions, because the limited output power of mm microwave sources, amplifiers, and mixers makes pulse FT EPR in that frequency domain impossible, at least for the near future. On the other hand, FT spectroscopy offers several advantages compared to field-swept magnetic resonance methods, as is demonstrated by its success in NMR and X-band EPR. In this paper we describe a novel stochastic W-band microwave bridge including a bimodal induction mode transmission resonator that serves for decoupling the microwave excitation and signal detection. We report first EPR measurements and discuss experimental difficulties as well as achieved sensitivity. Moreover, we discuss future improvements and the possibility for an application of stochastic W-band FT EPR to transient signals such as those of photoexcited radical pairs in photosynthetic reaction centers.

Fourier Analysis↗

RF coils for combined MR and hyperthermia studies: I. Hyperthermia applicator as an MR coil.

Combining hyperthermia, an experimental/adjuvant therapeutic modality for cancer, with the non-invasive metabolic studies using Magnetic Resonance (MR) is an interesting area of research. This two parts article discusses the development and testing of a conventional RF hyperthermia applicator for MR studies and vice versa. In this first part, an inductive type applicator known as 'Magnetrode' in RF hyperthermia has been used both as an MR volume resonator and a surface coil. Its concurrent performance as an hyperthermic applicator and an MR transmit/receive coil has been evaluated.

Fourier Analysis↗