PubMed HealthSearch

PubMed · 6570332

[Coronarography].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Volpilière, R Grolleau. 1984. [Coronarography].. https://pubmed.ncbi.nlm.nih.gov/6570332/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Coronary lumen at six-month follow-up of a new radiopaque Cordis tantalum stent using quantitative angiography and intracoronary ultrasound.

To determine the reliability of geometric (edge-detection) quantitative coronary angiographic analysis (QCA) of restenosis within a new Cordis tantalum stent, QCA and intracoronary ultrasound (ICUS) measurements were compared in both an experimental restenosis model and in the clinical follow-up of patients. In the experimental series, Plexiglas phantom vessels with concentric stenosis channels ranging from 0.75 to 3.0 mm in diameter and with a reference diameter of 3.0 mm were imaged both before and after their insertion in tantalum stents. In the clinical series, the agreement of QCA and ICUS measurements were studied in 23 patients who had undergone coronary implantation of the new tantalum stent and in 23 patients who had undergone balloon angioplasty 6 months previously. The reliability of QCA declined in the presence of the radiopaque stent (accuracy of QCA decreased from -0.07 to -0.12 mm), whereas the reliability of lumen measurements by ICUS was independent of the presence of the radiopaque stent (-0.12 and -0.13 mm). Without the stent, the average minimal luminal diameter (MLD) obtained by QCA of the 1.00 mm Plexiglas vessel was 1.00 +/- 0.01 mm, and the 3.00 mm reference vessel diameter was 2.81 +/- 0.05 mm, providing a 64 +/- 1% diameter stenosis. After introduction of the stent, the average MLD and reference vessel diameter were 0.99 +/- 0.06 and 3.36 +/- 0.17 mm, respectively, providing a diameter stenosis of 71 +/- 2%. ICUS measurements (2.77 mm) of the reference vessel diameter (3.00 mm) were unaffected by the presence of the stent.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Angiography

Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course?

BACKGROUND: The clinical significance of anomalously originating coronary arteries depends on their proximal course. Diagnosis of this course by conventional x-ray coronary angiography alone may be equivocal. We postulated that with fast magnetic resonance (MR) angiography, accurate detection of anomalous coronary arteries and unambiguous delineation of their proximal course is feasible. METHODS AND RESULTS: In a selected group of 38 patients, 19 of them having an anomalously originating coronary artery, a fast MR angiographic technique was used to study the proximal coronary anatomy. Blinded analysis of randomly ordered MR studies was performed independently by two observers. Both origin and proximal course of the coronary arteries were defined. Two cardiologists reviewed all x-ray coronary angiograms. After the separate analyses, a final consensus result was defined for each patient. In 37 patients, successful MR coronary angiography could be performed. Interobserver agreement for determining both origin and proximal course was 100%. An x-ray coronary angiogram was available in 36 patients. In 3 patients (all with an anomalous left main coronary artery originating from the right aortic sinus), there was disagreement about the proximal course between the results of MR and x-ray coronary angiography. Review of these cases demonstrated that MR angiography had unambiguously visualized the proximal coronary artery course, whereas the results of x-ray angiography had been equivocal. Thus, sensitivity and specificity for detecting anomalous coronary arteries and delineating their proximal course were 100%. CONCLUSIONS: These data suggest that fast MR angiography is highly accurate in determining the origin and delineating the proximal course of anomalous coronary arteries, even in those cases in which x-ray coronary angiographic diagnosis is difficult or even erroneous.

Coronary Angiography