PubMed HealthSearch

PubMed · 6575675

Speech encoding in the auditory nerve: implications for cochlear implants.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M B Sachs, E D Young, M I Miller. 1983. Speech encoding in the auditory nerve: implications for cochlear implants.. https://doi.org/10.1111/j.1749-6632.1983.tb31622.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of sympathetic activity, temperature, ischemia and diazepam on thermal and vibration thresholds.

In healthy volunteers thermal specific, thermal pain and vibration thresholds were assessed and correlated to each other and to sympathetic nervous system parameters. Additionally, different factors such as temperature, diazepam and ischemia affecting perception thresholds were evaluated. The thresholds assessed did not correlate significantly to each other and to sympathetic skin response latency or amplitude. Diazepam influenced the thermal specific, thermal pain and vibration thresholds assessed. The preingestion and postingestion (after 30, 60 and 90 minutes) thresholds did not differ significantly, meanwhile the scatter of thermal and vibration thresholds increased obviously. The skin temperature within the range of naturally occurring values of control subjects in a state of "thermal comfort" affected neither the warm-cold difference limen nor the heat and cold pain thresholds. Considerable temperature changes (the warming for 5 degrees C and cooling for 10 degrees C) influenced the vibration thresholds measured. Warming increased and cooling decreased the values recorded. Tourniquet-induced ischemia influenced only the vibration disappearance thresholds. Vibration perception and vibration thresholds varied but differences were not significant.

Auditory Threshold

Spontaneous otoacoustic emissions in an active feed-forward model of the cochlea.

Numerical simulation of spontaneous otoacoustic emissions (SOAE) was done using a 1-dimensional macromechanical cochlear model with an active 'feed-forward' force in every section of the basilar membrane (BM). When the activity of the force was increased the model showed more stability than a 'feed-back' model and could have excitation curves with larger tips without divergence of the solution. The stability broke up when either (1) the damping of the BM was made slightly irregular throughout the BM or (2) the feed-forward force was switched off at a certain part of the BM, and limit cycle oscillations (LCO) emerged within the cochlea. Critical feed-forward value for the emergence of LCO in the first setting of BM (1), which was intended to simulate physiological variations in the distribution of outer hair cells, was searched utilizing the 'ringing' of delayed evoked otoacoustic emissions (DEOAE). In the course of the search, smooth transition from a DEOAE to a set of SOAEs was found to occur keeping the same spectral fine structure of the emissions when the feed-forward force surpassed a certain value. It was, as a result suggested that the two kinds of emissions may have the same origin. In the second setting of BM (2), which was intended to simulate pathological cases. LCOs tended to be stronger than in the first one and they had similarity not only to real SOAEs but also to tinnitus in the way they showed up very close to or at the "edge' of the switched-off part of the BM.

Auditory Threshold

[Replacement of ear ossicles with titanium prostheses].

BACKGROUND: Titanium has been a well established implant material for many years. New material processing techniques now permit the manufacture of small implants for ossicular chain reconstruction. METHODS: Between November 1994 and September 1995, 100 titanium middle ear implants (55 PORP, 45 TORP) were used for reconstruction of the ossicular chain. A range of five different sizes for partial and total protheses suits all implantation needs. The shape of the implants can be altered by bending. Time consuming intraoperative shaping and trimming is avoided. RESULTS: At a follow-up time of three months (33 patients) and six months (17 patients), no adverse reactions or extrusions occurred. Biologic fixation between the foot of the partial prothesis and the head of the stapes was found eight months after implantation. A hearing result of 0-20 dB residual air-bone gap was achieved in 79%. CONCLUSION: Titanium middle ear implants show good bio-compatibility and are readily integrated into the ossicular chain. Although delicate in shape, they offer excellent mechanical properties in respect to sound conduction and implantation. Initial results show Titanium to be a perfect implant material for middle ear prostheses, although long-term results are not yet available.

Auditory Threshold