[Mechanical strain in the forearm bones].

Abstract

Knowledge of the physiologic distribution of strain in bone is essential for a successful osteosynthesis by means of compression plate. This method guarantees optimum stability if the plate acts as a tension band. If the side of tensile stresses varies within the bone, strain may not only occur on the side of the plate but also on the opposite cortex. In such cases the distribution of pressure in the fracture gap is of special importance. For determining the distribution of strain on the radius, it is necessary to examine the forces caused by the flexor- and extensor muscles of the wrist and fingers. Additional forces come also from flexor- and extensor muscles of the elbow. The frame formed by the bow-shaped radius and the ulna is of further importance for the distribution of strain. Kind and amount of tension is fundamentally influenced by forearm rotation. Anatomic studies on post-mortem specimens showed how the direction of muscle action to wrist and fingers changed in relation to the position of a plate fixed to the proximal shaft of the radius. This already demonstrates possible variations in the bending forces caused by forearm rotation. An analysis of the distribution of strain in the forearm bones was carried out on a biomechanical model using strain gauges. This method allows the simulation of strain to the skeleton caused by muscle force and the influence of load. The distribution of strain can be studied on the same model in various different positions of elbow and forearm. Six muscles and two muscle groups were simulated by means of wire pulls with calibrated strain gauges; these muscles and muscle groups act, on account of the physiological cross section and their position, as bending forces to the forearm bones in a dorsovolar plane. The tensile force on radius and ulna were each controlled by three strain gauges in four sections. The characteristic quantities of these sections were determined by evaluation of the appropriate computertomograms. With the aid of three strain gauges per section it was possible to assess the strain at any one desired point. Distribution of strain was determined by pull to each "muscle" in the extreme position of forearm rotation and three different positions of flexion to the elbow. The tensile force was expressed on graphs as muscle tension of 2 kp/cm2 per cross section (ill. 6 to 12).(ABSTRACT TRUNCATED AT 400 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Opitz. 1983. [Mechanical strain in the forearm bones].. https://pubmed.ncbi.nlm.nih.gov/6579803/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗