Small airways disease.

Abstract

Over the last 10 years the non-specific term "small airways disease" has been applied to a number of histologic lesions seen in the peripheral airways of smokers. It is becoming recognized that airway inflammation is the most important of these lesions. This pathology may be the precursor to the subsequent development of emphysema and is an important cause of the functional abnormality in smokers. A current hypothesis is that small airways disease may be detected early in the smoking careers of subjects who later develop chronic respiratory disability. In these individuals particularly, complete cessation of smoking should be the primary therapeutic goal. With the recent development of special tests to assess small airways function, the presence of small airways disease can be detected in asymptomatic smokers who may have normal routine lung function tests. However, most of the tests to assess airway function are also influenced by other physiological factors such as loss of elastic recoil. We await the results of long term epidemiological studies to confirm the above hypothesis that early small airways disease leads to chronic disability. Without such confirmatory evidence, the routine use of these special tests cannot at present be advocated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Berend. 1983. Small airways disease.. https://doi.org/10.1111/j.1445-5994.1983.tb04491.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correction of compliance and resistance altered by endotracheal tube leaks and non-linear pressure/volume-relationships.

Measurements of lung compliance (C) and resistance (R) are influenced by endotracheal tube leaks (ETTL) as well as non-linear pressure/volume relationships (P/V relationship). To keep C and R reliable, we developed an algorithm to mathematically correct inspiratory and expiratory volume (V) and flow. In this study, a ventilated lung model for non-linear P/V relationship with adjustment of an increasing ETTL was studied. In addition, the recordings (airway pressure, flow, and volume) of 21 infants (median weight: 1,220 g, range: 640-2,160 g, with a median leak size of 32%, range: 24-56%) were investigated. C and R were calculated continuously from the recordings of flow, volume, and airway pressure over time according to the changing volume. A method especially developed for the analysis of non-linear pressure-volume-relationship (APVNL) was employed. C and R affected by leaks were corrected applying the newly developed mathematical algorithm and compared with measurements without leakage. C could be corrected up to a leak of 80% and R up to 55% leak at half tidal V for the model with non-linear P/V-R. C and R without leak and after leak correction did not differ significantly in all infants where the APVNL method was applied (P > 0.05).

Airway Resistance↗

Parenchymal tethering, airway wall stiffness, and the dynamics of bronchoconstriction.

We do not yet have a good quantitative understanding of how the force-velocity properties of airway smooth muscle interact with the opposing loads of parenchymal tethering and airway wall stiffness to produce the dynamics of bronchoconstriction. We therefore developed a two-dimensional computational model of a dynamically narrowing airway embedded in uniformly elastic lung parenchyma and compared the predictions of the model to published measurements of airway resistance made in rats and rabbits during the development of bronchoconstriction following a bolus injection of methacholine. The model accurately reproduced the experimental time-courses of airway resistance as a function of both lung inflation pressure and tidal volume. The model also showed that the stiffness of the airway wall is similar in rats and rabbits, and significantly greater than that of the lung parenchyma. Our results indicate that the main features of the dynamical nature of bronchoconstriction in vivo can be understood in terms of the classic Hill force-velocity relationship operating against elastic loads provided by the surrounding lung parenchyma and an airway wall that is stiffer than the parenchyma.

Airway Resistance↗

Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.

OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.

Airway Resistance↗