PubMed HealthSearch

PubMed · 6587722

Cardiovascular changes in pre-eclampsia.

Abstract

Pre-eclampsia is associated with a hyperdynamic circulation (increased cardiac output, systemic vascular resistance) and increased mean arterial blood pressure, and a diminished plasma volume. Expansion of plasma volume without simultaneous measures on circulation or proper monitoring may be detrimental, leading to pulmonary and brain edema.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Carlsson. 1984. Cardiovascular changes in pre-eclampsia.. https://doi.org/10.3109/00016348409157138

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lack of reproducibility in pregnancy of Korotkoff phase IV as measured by mercury sphygmomanometry.

BACKGROUND: Since hypertensive disorders of pregnancy are common, blood pressure is frequently measured in all pregnant women. Many authorities recommend that Korotkoff phase IV (K4, muffling of sound) is taken as the diastolic identification point measured on mercury sphygmomanometry in pregnancy because of reports that phase V (K5, disappearance of sound) is at or near to zero cuff pressure in some pregnant women. We compared the identification and reproducibility of K4 and K5 by observers unaware of each other's results. METHODS: In the first part of the study, two pairs of observers each took 340 measurements in 85 pregnant women. The second part of the study consisted of 1120 measurements in 80 pregnant and 80 non-pregnant women by five pairs of observers. Measurements were taken simultaneously by sphygmomanometry with a shared cuff and diaphragm; the observers were in separate booths. FINDINGS: K5 was identified in all measurements by both observers and never approached zero. K4 was heard in only 52% of measurements; in 33% of cases it was heard by only one of the pair of observers, so the pair agreed on its detection in only 19% of readings. Visual analogue scores used to assess Korotkoff sound quality indicated that systolic blood pressure was perceived significantly more clearly than diastolic blood pressure (K4 or K5). Even when K4 was heard by both observers, agreement on its value was poor (78% within 5 mm Hg vs 86% for K5, p < 0.05). K4 was heard significantly less often in non-pregnant women (32% of measurements). There was also no consistency in the identification of K4 within individual women. INTERPRETATION: K4 has little value in clinical management because it cannot be reproduced accurately. We recommend that K4 should be replaced by K5 as the measure of diastolic blood pressure in pregnancy.

Blood Pressure

Effect of ligation of patent ductus arteriosus on left ventricular performance and its determinants in premature neonates.

OBJECTIVES: The purpose of this study was to determine in preterm newborn infants the effects of ductal ligation on ventricular performance and its determinants: preload, afterload and contractility. BACKGROUND: Neonatal ventricular performance is highly sensitive to afterload. Therefore, the increase in systemic vascular resistance associated with ligation of a patent ductus arteriosus might worsen ventricular performance in the preterm infant. METHODS: All 14 premature infants undergoing patent ductus arteriosus ligation in a 1-year period at our institution underwent echocardiography at three times: before, immediately after and 24 h after ligation. Indexes studied included ventricular performance (fractional area change), preload (left ventricular end-diastolic dimension), afterload (end-systolic wall stress) and contractility (the difference between the measured and predicted velocity of circumferential fiber shortening). Blood pressure was measured; systemic resistance was calculated. These data were compared with those of 14 preterm infants without patent ductus arteriosus. RESULTS: The infants with patent ductus arteriosus had higher values for ventricular performance (mean +/- SD fractional area change 60 +/- 9% vs. 52 +/- 11%, p < 0.05) and lower values for wall stress (22 +/- 6 vs. 44 +/- 17 g/cm2, p < 0.05) before ligation than did the control group. At 24 h after ligation, ventricular performance was not significantly changed (fractional area change 60 +/- 9% to 57 +/- 12%). There were significant increases in blood pressure and systemic vascular resistance but no changes in wall stress or contractility. CONCLUSIONS: Ventricular performance is higher in premature infants with than in those without patent ductus arteriosus because afterload is lower in the former group. Although ductal ligation increases blood pressure and systemic resistance, wall stress and ventricular performance are maintained. Our results suggest that the premature newborn maintains ventricular performance during stress, at least in part, by manipulating afterload.

Blood Pressure