Background visibility and increment thresholds.

Abstract

Increment thresholds for small test flashes measured on superimposed backgrounds sometimes differed depending on whether an observer was instructed to keep the background subjectively visible or (Troxler) faded. The magnitude and direction of the threshold change varied among observers. For some observers, the magnitude of the effect of such instructions also varied with background size, psychophysical method, and displacement of test from background. How the instructions and their presumed association with different phenomenological states affect thresholds is not known. However, these results show that the magnitude of effects and the shapes of psychophysically measured functions can be affected by the instructions followed by the observer, whether self-imposed or imposed by the experimenter.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S L Buck, W Makous, T Piantanida. 1983. Background visibility and increment thresholds.. https://doi.org/10.1016/0042-6989(83)90023-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Mesoptic vision in multi- and monofocal pseudophakia and in phakic control eyes].

UNLABELLED: The mesopic visual acuity (MVA) after intraocular lens (IOL) implantation is reduced compared to phakic patients of the same age. However, previous studies from our clinic have shown no significant MVA difference between multi- and monofocal IOLs. In the present study (with the patients matched exactly for age), this topic was reevaluated. PATIENTS AND METHODS: We investigated three groups, each consisting of 28 persons, 51 to 60 years of age. Group I consisted of healthy phakic volunteers, group II of patients 3 months after cataract extraction and implantation of a monofocal posterior chamber IOL (Pharmacia 720A) and group III of patients 3 months after implantation of a diffractive multifocal posterior chamber IOL with biconvex optic configuration (3M 825X). The MVA was examined using the "Ocutrast," described by Nowak. The Ocutrast, a modification of the Mesoptometer II, provides a field luminance of 1 cd/m2 and a contrast of 1:23 between test optotype and background; the intensity of illumination under glare conditions amounts to 0.35 lx at the level of the pupil. RESULTS: The MVA without glare amounted to 0.50 +/- 0.12 (group I, healthy phakic eyes), 0.45 +/- 0.15 (group II, monofocal IOLs) and 0.32 +/- 0.11 (group III, multifocal IOLs). The MVA with glare amounted to 0.47 +/- 0.08 (group I), 0.35 +/- 0.12 (group II) and 0.24 +/- 0.10 (group III). Both for the MVA with and without glare there was a significant group difference (P < 0.05; two-factor analysis of covariance with repeated measurements). CONCLUSIONS: After implantation of diffractive multifocal IOLs of the presently used type (3M 825X), the mesopic vision--both with and without glare--is even more reduced than after monofocal IOL implantation. These findings are particularly relevant for aged pseudophakic car drivers, especially for driving at night.

Dark Adaptation

Predicting outcome in central retinal vein occlusion using the flicker electroretinogram.

OBJECTIVE: To evaluate the usefulness of the 30-Hz flicker electroretinogram (ERG) in predicting outcome in patients with central retinal vein occlusion using an automated system previously developed to measure parameters of the flicker ERG and using information about the a priori probability of developing neovascularization of the iris in central retinal vein occlusion. METHODS: Amplitude and timing were extracted from 30-Hz flicker ERGs of 76 patients with acute central retinal vein occlusion from a previous study. The ability of the ERG to predict the development of neovascularization of the iris based on derived parameters was measured using the area under the receiver operating characteristic curve. RESULTS: The predictive ability of the 30-Hz ERG amplitude, as judged by a two-alternative forced-choice procedure, was 92%. The corresponding value for implicit time was 89%. Using Bayes' theorem, we computed the probability of developing neovascularization of the iris based on a single 30-Hz flicker ERG measurement at initial patient presentation. CONCLUSIONS: The 30-Hz flicker ERG provides useful information about the patients with central retinal vein occlusion.

Dark Adaptation