PubMed HealthSearch

PubMed · 6689122

Angle resolved fluorescence depolarization experiments on oriented lipid membrane systems.

Abstract

It is demonstrated that angle resolved steady state fluorescence depolarization experiments on oriented lipid membrane systems can be an useful alternative to time-resolved fluorescence depolarization experiments on vesicles. It is shown that some basic assumptions underlying time-resolved experiments are not always valid. The usefulness of the measurement of an additional order parameter, less than P4 greater than is demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Vos, R P Kooyman, Y K Levine. 1983-10-31. Angle resolved fluorescence depolarization experiments on oriented lipid membrane systems.. https://doi.org/10.1016/0006-291x(83)90546-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Principal components describing biological activities and molecular diversity of heterocyclic aromatic ring fragments.

Ten physicochemical variables have been calculated for each of 100 different aromatic rings. These variables were selected because of their potential involvement in the molecular recognition of drug-receptor binding interactions, and they include size, lipophilicity, dipole magnitude and orientation, HOMO and LUMO energies, and electronic point charges. A total of 59 different aromatic ring systems were studied including monocyclics and [5.5]-, [6.5]- and [6.6]-fused bicyclics. A principal components analysis of b1ese results generated four principal components which account for 84% of the total variance in the data. These principal components provide a quantitative measure of molecular diversity, and their relevance for structure-activity relationships is discussed. The principal components correlate with the in vitro biological activity of heterocyclic aromatic fragments within a series of previously reported HIV-1 reverse transcriptase inhibitors.

Chemical Phenomena

Temperature dependence of the isotope chemistry of the heavy elements.

The temperature coefficient of equilibrium isotope fractionation in the heavy elements is shown to be larger at high temperatures than that expected from the well-studied vibrational isotope effects. The difference in the isotopic behavior of the heavy elements as compared with the light elements is due to the large nuclear isotope field shifts in the heavy elements. The field shifts introduce new mechanisms for maxima, minima, crossovers, and large mass-independent isotope effects in the isotope chemistry of the heavy elements. The generalizations are illustrated by the temperature dependence of the isotopic fractionation in the redox reaction between U(VI) and U(IV) ions.

Chemical Phenomena

Quantitative determination of total molar concentrations of bioaccumulatable organic micropollutants in water using C18 empore disk and molar detection techniques.

A highly sensitive and quantitative group parameter to determine total molar concentrations of organic micropollutants that can bioaccumulate in the lipid phase of aquatic organisms from effluents, surface water, and drinking water has been developed. C18 empore disk was used as a surrogate lipid phase. The partition process between water and C18 empore disk was employed to simulate the bioaccumulation process. After partition extraction of the water sample, the empore disk was extracted with cyclohexane, and total molar concentrations were determined in these extracts using vapor pressure osmometry (VPO) and gas chromatography/mass spectrometry (GC/MS), respectively. Total molar concentrations bioaccumulated in aquatic biota were estimated from the cyclohexane concentrations. Good accuracy for the total molar determination was obtained using VPO, due to the practically constant molar response factors (43.1 +/- 1.7 V/M) for a wide compound range and to excellent additivity of individual compound responses. Satisfying reproducibility (0-8.3%) of VPO was obtained for sample extracts. The detection limit of VPO in cyclohexane extracts corresponded to 0.60 mM in the lipid phase of aquatic biota. A minimal separation GC/MS system was developed, which enabled highly sensitive and sufficiently accurate total molar determinations. The reproducibility of the GC/MS determination for samples ranged from 0.7 to 22%. The detection limit of GC/MS in cyclohexane extracts corresponded to 0.044 mM in the lipid phase. The determined total molar concentrations in the lipid phase of aquatic biota were in the range of 0.139-168 mM for effluents, 0.26-1.34 mM for surface water systems, and < 0.044 mM for drinking water.

Chemical Phenomena