Methods for extracting phospholipids from human amniotic fluid compared.

Abstract

Phospholipids were extracted from human amniotic fluid by various procedures, including the two most commonly applied to amniotic fluid for evaluation of fetal lung maturity. We find that the yield of phospholipid is greatly procedure dependent. This should be taken into account when one is considering the various reported methods of evaluating fetal lung maturity, because in some of them phospholipid data are expressed in terms of absolute concentration in the amniotic fluid. There were also significant differences in phospholipid composition in extracts prepared by the various procedures, but in general these were not large enough to influence evaluation of fetal lung maturity by methods in which phospholipid data are expressed in relative terms, as ratios or percentages--e.g., in the lecithin/sphingomyelin ratio and "lung profile" procedures. In the extraction method originally recommended for determination of the lecithin/sphingomyelin ratio, both the yield and composition of phospholipid depend on the extent of mixing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C G Duck-Chong, G J Baker, S R Murdoch, R M Price. 1984. Methods for extracting phospholipids from human amniotic fluid compared.. https://pubmed.ncbi.nlm.nih.gov/6692532/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Maternal and fetal levels of methionine and homocysteine in early human pregnancy.

OBJECTIVE: To investigate methionine metabolism during normal human embryonic development by measuring levels of methionine and total homocysteine in samples of maternal serum, extra-embryonic coelomic fluid, and amniotic fluid. DESIGN: Cross-sectional observational study. SETTING: Collaboration between St Bartholomew's Hospital, London, and the University Hospital of Nijmegen in The Netherlands. PARTICIPANTS: Twenty-three women with uncomplicated pregnancies between 8 and 12 weeks of gestation before surgical termination of an ultrasonographically normal fetus. METHODS: Maternal serum samples were collected prior to surgery. Samples of extra-embryonic fluid and amniotic fluids were obtained by transvaginal ultrasound-guided coelocentesis and amniocentesis. Methionine was measured using an amino acid analyser and total homocysteine by high performance liquid chromatography. RESULTS: Levels of methionine were four times higher in extra-embryonic coelomic fluid and twice as high in amniotic fluid compared with maternal serum. In contrast, the total homocysteine concentrations were much lower in both extra-embryonic coelomic fluid and amniotic fluid than in maternal serum. All differences were significant (P < or = 0.01). CONCLUSIONS: The comparatively high concentrations of methionine in extra-embryonic coelomic fluid and amniotic fluid, and the concomitant low levels of total homocysteine in these fluids, suggest a role for methionine metabolism during early human pregnancy.

Amniotic Fluid

Granulocyte-macrophage colony-stimulating factor in amniotic fluid and in airway specimens of newborn infants.

Granulocyte-macrophage colony-stimulating factor (GM-CSF), a cytokine that promotes white cell maturation, participates in the metabolism of pulmonary surfactant. Little is known on the production of GM-CSF during pregnancy or the neonatal period. We studied how the concentrations of GM-CSF in amniotic fluid (AF) or in tracheal aspirates (TA) of newborn infants are influenced by length of gestation, postnatal age, as well as conditions affecting the mother or the fetus. One hundred and forty-three AF samples from 143 pregnant patients (gestational age range, 28-42 wk) and 202 TA samples from 82 neonates (gestational age, 24-42.5 wk, postnatal age 0.2 d to 4 wk) were analyzed for GM-CSF using ELISA. In patients with intact membranes, AF GM-CSF increased as a function of gestational age; the concentrations were below 7.5 ng/L (detection limit of the assay) (n = 5), 18.6 +/- 2.3 ng/L (n = 56), and 56.7 +/- 7.9 ng/L (n = 58) at gestational ages between 28 and 32 wk, between 32 and 37 wk, and in term patients, respectively (linear regression: r = 0.404, p = 0.001). Among patients at less than 33 wk of gestation, those with intact membranes had a median AF GM-CSF concentration under the detection limit (n = 7), whereas in those with preterm premature rupture of membranes, the concentration was 50.1 +/- 22.2 ng/L (n = 16) (p = 0.002). Among term patients, those in labor had higher AF GM-CSF than those without signs of labor. TA GM-CSF at less than 12 h of age correlated with gestational age (r = 0.654, p = 0.0002, n = 28); thereafter, TA GM-CSF increased, and gestation dependence disappeared. We conclude that GM-CSF in AF and in fetal lung liquid is developmentally regulated and GM-CSF production increases in inflammatory conditions during pregnancy.

Amniotic Fluid