PubMed Health⌕ Search

PubMed · 6703048

Electronic device for microelectrode recordings in epithelial cells.

Abstract

A device is described that permits continuous measurement of electrophysiological parameters in epithelial tissues in the open-circuit mode. Transepithelial potential (VT) and microelectrode (either conventional or ion-selective) potential (VM) are directly measured. Application of transepithelial current pulses allows continuous monitoring of transepithelial resistance (RT) and the ratio between the changes in VM and VT induced by these pulses. Measurement of this ratio, which under some circumstances reflects the apical fractional resistance of the cellular pathway, is important in assessing membrane damage during microelectrode impalement and/or as an index that the microelectrode tip is inside a cell. This is particularly useful when the change in VM during impalement is small. Application of 0.5-nA current pulses through open-tip microelectrodes allows continuous recording of the microelectrode resistance (RM). In epithelia where the individual cells are electrically coupled this permits acceptable impalements (RM remains nearly constant) to be distinguished from those affected by tip potential artifacts due to plugging of the microelectrode tip (RM increases after penetration of the cell membrane). The device provides compensation for the IR voltage drop in the solution between the potential measuring salt bridges and the epithelial surfaces. The microelectrode electrometer has an input impedance greater than 10(15) and is provided with stray capacitance neutralization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Garcia-Diaz, S Stump, W M Armstrong. 1984. Electronic device for microelectrode recordings in epithelial cells.. https://doi.org/10.1152/ajpcell.1984.246.3.c339

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acute effects of estrogen on neuronal physiology.

It has been known for more than 30 years that estrogen can alter the intrinsic and synaptic physiology of neurons within minutes. The physiological significance of these acute effects has been unclear, however, because some effects require higher concentrations of estrogen than are detected in plasma, and because estrogen secreted by the ovary rises and falls over a time course of days, not minutes. These concerns may be answered by new research demonstrating that estrogen is produced at high levels within the brain itself, and that production of estrogen in the brain may be regulated by neuronal activity. Additionally, recent studies indicate that classical estrogen receptor proteins are found not only in the nucleus where they regulate gene expression but also at extranuclear sites, including at synapses. These findings, together with evidence for new types of extranuclear estrogen receptors, suggest that estrogen might act directly at synapses to activate second messenger signaling, thereby rapidly altering neuronal excitability, synaptic transmission, and/or synaptic plasticity.

Electrophysiology↗