Abstract

To obtain verification of the proper time setting of the motorized run down timer for a AECL 780 Cobalt Unit, a digital timer is described, which can be added to the system for under $300.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J B Smathers, F E Holly. 1984. Verification timer for AECL 780 Cobalt unit.. https://doi.org/10.1016/0360-3016(84)90307-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A modified 60C teletherapy unit for total body irradiation.

PURPOSE: A modified teletherapy unit to achieve total body irradiation with a vertical beam in a conventional treatment room. METHODS AND MATERIALS: A standard 60C teletherapy unit has been modified to achieve total body irradiation with a vertical beam in a conventional treatment room. Patients are treated in prone and supine positions. Removal of the adjustable collimator assembly of this standard machine provides a circular field of 196 cm in diameter at 167 cm from the source. Second, the machine has been elevated by about 50 cm on a metallic base to enlarge irradiation field to obtain 248 cm in diameter at 210 cm from the source, and to encompass tall patients under better conditions. A special lead conical beam flattening filter, 10-mm thick at the center, was designed to compensate the spatial inhomogeneity of the beam. An instantaneous dose rate of 6.10(-2) Gy/min is attained at the L4 level (midplane) in an average 20-cm thick patient with a source activity of 5099 RHM (air kerma rate of 44.8 Gy.h-1.m2). Between February 2, 1984 and December 27, 1990, 244 total body irradiations were performed either by single dose (n = 69, 10 Gy were given to midplane at L4 level in about 6 to 8 h, 8 Gy to the lungs), or by fractionated dose (n = 175, 12 Gy were given in 6 fractions over 3 consecutive days to midplane at L4 level, 9 Gy to the lungs). RESULTS: The dose distribution is similar than the ones obtained by a linear accelerator with patients lying on their sides. CONCLUSION: Patients were treated in a comfortable and highly reproductible position. Organ shielding was easily achievable. This could be a less expensive and reasonable alternative to linear accelerator.

Cobalt Radioisotopes

TLD postal dose intercomparison for megavoltage units in Poland.

The aim of the TLD pilot study was to investigate and to reduce the uncertainties involved in the measurements of absorbed dose and to improve the consistency in dose determination in the regional radiotherapy centres in Poland. The intercomparison was organized by the SSDL. It covered absorbed dose measurements under reference conditions for Co-60, high energy X-rays and electron beams. LiF powder type MT-N was used for the irradiations and read with the Harshaw TLD reader model 2000B/2000C. The TLD system was set up and an analysis of the factors influencing the accuracy of absorbed dose measurements with TL-detectors was performed to evaluate and minimize the measurement uncertainty. A fading not exceeding 2% in 12 weeks was found. The relative energy correction factor did not exceed 3% for X-rays in the range 4-15 MV, and 4% for electron beams between 6 and 20 MeV. A total of 34 beams was checked. Deviation of +/- 3.5% stated and evaluated dose was considered acceptable for photons and +/- 5% for electron beams. The results for Co-60, high energy X-rays and electron beams showed that there were two, three and no centres, respectively, beyond acceptance levels. The sources of errors for all deviations out of this range were thoroughly investigated, discussed and corrected, however two deviations remained unexplained. The pilot study resulted in an improvement of the accuracy and consistency of dosimetry in Poland.

Cobalt Radioisotopes