Lateral ventricular volumes were measured on magnetic resonance imaging (MRI) scans by independent raters in 18 subjects (11 psychotic patients and 7 healthy control subjects) with two different approaches: a point-counting stereological (PCS) technique and a computerized technique based on segmentation algorithms. The correlation between the two techniques was very high (r = 0.96), and phantom studies showed good validity for both approaches. These findings and the technical simplicity of the PCS technique support its potential use for MRI morphometric measurements.

Cerebral Ventricles

Delayed intrapleural migration of a ventriculoperitoneal shunt.

We report a case of delayed intrapleural migration of the peritoneal catheter of a ventriculoperitoneal shunt. This is an unusual but life-threatening complication of peritoneal shunting for the treatment of hydrocephalus. A method of treatment and abbreviated review of shunt complications is included.