Step-rotation therapy: a technique for linear accelerators.

Abstract

Rotation therapy has been accepted as a standard method of treatment for many years, but is use has been confined almost entirely to telecobalt therapy. This has been due to the difficulty in maintaining a constant output, and therefore a constant dose per degree of gantry rotation, when using a linear accelerator. This paper presents a new form of step-rotation therapy avoids this difficulty and is suitable for use with any modern linac to which remote gantry drive has been added. Apart from the advantages of smaller penumbra and shorter treating time on linear accelerator, in this technique both computation and delivery of dose is done in steps, and therefore the computed dose distribution matches the actual expected distribution. A further advantage is the ability to change the weighting at each step, which gives more control over the final distribution. Other problems which have been inherent in telecobalt rotation therapy are also avoided, such as matching treatment time and arcing time, and correcting for the discrepancies resulting from mismatch.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C W Smith, W H Sutherland, B C Warren. 1980. Step-rotation therapy: a technique for linear accelerators.. https://doi.org/10.1016/s0009-9260(80)80187-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dose equivalent measurements at a 2.7 GeV proton accelerator and comparison with the Moyer model.

The Moyer model, based on a semi-empirical method validated in the 7.4 to 350 GeV energy range, is generally used to calculate lateral shielding for high energy proton accelerators. Measurements made for the Saclay Synchrocyclotron, Saturne, have enabled the parameters corresponding to a 2.7 GeV model to be studied for different target thicknesses and angles of observation. These studies show how new data have been used to modify the equations of the model.

Particle Accelerators

Constancy of wedge factors in a Siemens Mevatron 74 linear accelerator.

The variation of the wedge factor (WF) with field size is an important piece of data which determines the radiation output in treatments using wedge filters. WF is closely related with the accelerator head layout, and the choice of the wedge tray mounted above or below the jaws plays a predominant role. In this work we have studied the WF variations in our linac and found that, in apparent contradiction with the literature, the WF remains constant with field size. Nevertheless, these results cannot be used directly in other linacs, and individual dosimetry must be carried out.

Particle Accelerators

Dosimetric accuracy of a dual photon energy linac at low monitor setting for various pulse repetition frequencies.

Accuracy of dose delivery at low monitor unit setting is studied for a dual photon energy linear accelerator. Dose delivered per MU is found to be constant for both the photon beams for MU settings above 30. For lower MUs there is definite deviation from the calibrated value and the error is found to be increasing as fewer MUs are set for dose delivery. This dose/MU ratio at low MU setting is found to be dose-rate dependent, showing an increasing trend with pulse repetition frequency (PRF). Also, the dosimetric ratio is observed to be mode dependent; its value for an 18 MV beam is almost double that observed in the case of a 6 MV beam at very low MU setting. The magnitude of this error should be determined for each energy so that appropriate corrections can be applied if very low MUs are to be used.

Particle Accelerators