PubMed Health⌕ Search

PubMed · 6803852

Buffer electrofocusing of Interleukin I.

Abstract

Buffer electrofocusing, utilizing a mixture of low-molecular-weight buffer compounds to establish a stable linear pH gradient covering the range 3.5-6.0 on granulated gel media, has been employed in the purification of Interleukin I with good recovery of biological activity. The difficulties often experienced in the removal of commercial synthetic ampholytes after conventional preparative electrofocusing are avoided in this method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Prestidge, W J Koopman, J C Bennett, M T Hearn. 1982. Buffer electrofocusing of Interleukin I.. https://doi.org/10.1007/bf01136723

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On the possibility of applying noncovalent dyes for protein labeling in isoelectric focusing.

Noncovalent fluorescent dyes are widely used for protein quantification and postcolumn detection in electrophoretic separations and recently some attempts to separate the precolumn labeled proteins using isoelectric focusing (IEF) have been made. In the present study, the possibility of applying the technique of protein labeling with noncovalent dyes for IEF is investigated. We found that fluorescent signal emitted by NanoOrange dye increases essentially in presence of carrier ampholyte (CA) components, which makes problematic a reliable protein detection in CA environment. Since in an isoelectric focusing mode the CA species are present in much greater concentration than the concentrations of fractionated proteins, the method of protein labeling with NanoOrange is not suitable for precolumn labeling and cannot be used for CA-IEF, at least without more detailed study of the dye-protein interaction mechanism.

Ampholyte Mixtures↗

High-resolution computer simulation of the dynamics of isoelectric focusing using carrier ampholytes: focusing with concurrent electrophoretic mobilization is an isotachophoretic process.

Focusing of four hemoglobins with concurrent electrophoretic mobilization was studied by computer simulation. A dynamic electrophoresis simulator was first used to provide a detailed description of focusing in a 100-carrier component, pH 6-8 gradient using phosphoric acid as anolyte and NaOH as catholyte. These results are compared to an identical simulation except that the catholyte contained both NaOH and NaCl. A stationary, steady-state distribution of carrier components and hemoglobins is produced in the first configuration. In the second, the chloride ion migrates into and through the separation space. It is shown that even under these conditions of chloride ion flux a pH gradient forms. All amphoteric species acquire a slight positive charge upon focusing and the whole pattern is mobilized towards the cathode. The cathodic gradient end is stable whereas the anodic end is gradually degrading due to the continuous accumulation of chloride. The data illustrate that the mobilization is a cationic isotachophoretic process with the sodium ion being the leading cation. The peak height of the hemoglobin zones decreases somewhat upon mobilization, but the zones retain a relatively sharp profile, thus facilitating detection. The electropherograms that would be produced by whole column imaging and by a single detector placed at different locations along the focusing column are presented and show that focusing can be commenced with NaCl present in the catholyte at the beginning of the experiment. However, this may require detector placement on the cathodic side of the catholyte/sample mixture interface.

Ampholyte Mixtures↗

Protein tryptic digests analyzed by carrier ampholyte-based capillary electrophoresis coupled to ESI-MS.

In this study, narrow pH cuts of carrier ampholytes have been used as buffers in CE for the analysis of protein tryptic digests. Their low conductivity allows very efficient separations under high electric field strength without inducing any significant Joule heating. In this study, the capabilities of narrow pH cuts of carrier ampholytes for the separation of protein tryptic digests have been assessed. Three proteins of different molecular masses have been studied: cytochrome C (horse heart), beta-lactoglobulin B (bovine) and human transferrin. Efficient, rapid and repeatable separations of the peptides resulting from the tryptic digestion have been achieved in this buffer. Moreover, the feasibility of the coupling of carrier ampholyte-based capillary electrophoresis with ESI-MS has been demonstrated through the study of the cytochrome C tryptic digest.

Ampholyte Mixtures↗