PubMed Health⌕ Search

PubMed · 6804486

Solid-phase Clq-binding fluorescence immunoassay for detection of circulating immune complexes.

Abstract

A fluorescence immunoassay for detection of immune complexes bound to solid-phase C1q was developed. The method was standardized by using human aggregated immunoglobulin G (IgG) to simulate immune complexes. A linear relationship existed between the concentrations of the aggregated IgG standards and the resulting fluorescent intensity. The method was found to be reproducible and capable of detecting as little as 10 micrograms of aggregated IgG per ml of heat-inactivated human serum. Antigen-antibody complexes prepared in vitro were detectable from equivalence to moderate antigen excess. Endogenous serum C1q inhibited the binding of aggregated IgG to solid-phase C1q. Pretreatment of test sera with EDTA was ineffective in eliminating this competitive effect. Heating the sera at 56 degrees C alleviated, but did not abolish, interference of endogenous C1q. Elevated levels of immune complexes were detectable in sera fro seven of nine patients wit systemic lupus erythematosus, provided the samples were heat inactivated before testing. Heparin and DNA were also found to interfere with the detection of aggregated IgG added to human serum. Assay values were falsely decreased due to competitive inhibition by these anions. Lipopolysaccharides from a variety of bacterial preparations produced no detectable interference. A comparative study was conducted on samples that had previously been tested by fluid-phase C1q-binding radioimmunoassay. The two methods were concordant in assigning normal or elevated levels of immune complexes in 70% of the samples tested. This solid-phase fluorescence immunoassay is proposed as a possible alternative to radioimmunoassay for the detection of circulating immune complexes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M M Collins, C H Casavant, D P Stites. 1982. Solid-phase Clq-binding fluorescence immunoassay for detection of circulating immune complexes.. https://doi.org/10.1128/jcm.15.3.456-464.1982

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune complexes suppress IFN-gamma signaling by activation of the FcgammaRI pathway.

Antigen-driven immune responses are modulated by immune complexes (ICs), in part through their ability to inhibit IFN-gamma-dependent MHC Class II expression. We have demonstrated previously that ICs dramatically inhibit IFN-gamma-induced activation of human monocytes through the suppression of the JAK/STAT signaling pathway. In the current study, we further explore the mechanisms by which ICs regulate IFN-gamma activation of human monocytes. Consistent with previous studies in monocytes pretreated with ICs, there was a reduction in steady-state levels of RNA by real-time RT-PCR of the IFN-inducible protein 10 gene as well as the FcgammaRI gene. Pull-down assays confirm that IC pretreatment inhibits IFN-gamma-induced STAT1 phosphorylation without affecting the ability of STAT1 to bind to the STAT1-binding domain of the IFN-gamma receptor. In addition, the inhibitory function of ICs was reduced when cells from the FcR common gamma-chain knockout mice were used, supporting the role of the FcgammaRI in this inhibitory pathway. It is unexpected that ICs also require the phosphatase Src homology-2-containing tyrosine phosphatase 1 (SHP-1) to inhibit IFN-gamma induction, as demonstrated by studies with cells from the SHP-1 knockout (motheaten) mice. These data suggest a mechanism of IC-mediated inhibition of IFN-gamma signaling, which requires the ITAM-containing FcgammaRI, as well as the ITIM-dependent phosphatase SHP-1, ultimately resulting in the suppression of STAT1 phosphorylation.

Antigen-Antibody Complex↗

Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase.

In order to increase the sensitivity of liquid chromatography/mass spectrometry (LC/MS) assays of recombinant proteins for pharmacokinetics studies, we have developed an immuno-mass spectrometry assay for EPI-hNE4, a 6237 Da protein currently developed for respiratory distress syndromes. After immunocapture of the analyte in human plasma with magnetic beads coated with anti-EPI-hNE4 antibodies, the intact protein was eluted and separated in reversed-phase LC and then analysed by tandem mass spectrometry (MS/MS) in selected reaction monitoring (SRM) mode. The problem of analytical interference due to endogenous binding antibodies was addressed by successive steps of acidification and neutralisation before immunocapture. Furthermore, potential variations in the recovery of analyte during sample extraction were compensated for by addition of an internal standard recognised by the antibodies. The precision of the assay remained therefore below 15%. A significant increase in assay sensitivity was achieved since the extraction step allowed sample concentration and removal of matrix components interfering with the electrospray ionisation process. Using 0.4 mL of plasma, a limit of quantification at 0.5 ng/mL (80 pM) was reached, which represents a 10-fold improvement in sensitivity over our previous work using sample precipitation. This technique was able to monitor EPI-hNE4 kinetics in the plasma of human subjects for 36 h after an intravenous administration of 0.125 mg/kg.

Antigen-Antibody Complex↗

Antibody arrays for quantitative immunophenotyping.

Detection of multiple surface antigens expressed on living cell is an important step for cell processing and clinical diagnosis. Here we describe the preparation of antibody arrays that allow parallel detection of multiple surface antigens through affinity binding of living cells. An antibody array was fabricated by photo-assisted patterning of an alkanethiol monolayer formed on a gold-coated glass plate and subsequent immobilization of antibodies specific for cell surface antigens in an array format. We demonstrate here that rapid phenotyping can be performed on the array for both adhesion-dependent and non-dependent cells by direct cell binding assays. The density of bound cells on each antibody spot was in accordance with their contents in an original suspension. This result suggests the feasibility of the array-based method for quantitative assessment of multiple antigen expression. These findings will serve to extend the range of fundamental and clinical applications of antibody arrays.

Antigen-Antibody Complex↗