A multiple-electrode cochlear implant.

Abstract

A multiple-electrode cochlear implant comprised of three intracochlear and four extracochlear electrodes is described. A percutaneous plug allowed for direct electrical measurements and presentation of stimuli to selected electrode combinations. Electrical impedance measurements revealed functions that decreased as frequency increase to about 20 kHz. Absolute impedance magnitude varied across electrodes. Equal loudness contours were similar in shape for all three cochlear electrodes, although dynamic range was significantly reduced for the most apical electrode. Periodicity and place pitch were demonstrated; effects were most salient for low frequency stimuli. A 3-channel sound processor was built and multiple-channel stimulation was compared to single-channel stimulation. Significant performance differences were not found between single-channel and multiple-channel systems for environmental or speech sounds. However, the patient subjectively reported superior quality with the multiple-channel system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W F House, B J Edgerton. A multiple-electrode cochlear implant.. https://pubmed.ncbi.nlm.nih.gov/6805389/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Manifestations of intense noise stimulation on spontaneous otoacoustic emission and threshold microstructure: experiment and model.

Comparison between changes that occur simultaneously on spontaneous otoacoustic emissions (SOAEs) and on other cochlear origin phenomena can contribute to the understanding of cochlear micromechanical activity. The temporary changes that arise after short noise exposure are investigated in the following paper. The effects of noise exposure on the threshold microstructure near an SOAE and on the amplitude and frequency of the SOAE were measured. These experimental results indicate the following: (1) exposure to wideband noise for a short time causes a temporary reduction in the SOAE frequency and amplitude, and alters reversibly the threshold microstructure in the vicinity of the SOAE. The difference between the minimum and maximum in the threshold microstructure is reduced, and the frequency that yields the minimum threshold decreases; (2) the threshold at the SOAE frequency is most sensitive to noise exposure; (3) intense stimulation causes a relatively small increase, or even a decrease, in threshold at frequencies near the SOAE. The experimental results are interpreted in terms of a nonlinear transmission line model which includes nonlinear amplifiers. The effect of the noise exposure is modeled by reduction in the cochlear partition amplification term. Most of the experimental results are predicted by this model.

Auditory Fatigue

Prediction of deterioration in hearing due to hearing aid use.

There is a definite risk of overamplification by hearing aids. Guidelines should therefore be established that will minimize the risk of damage to hearing involved in hearing aid use. A mathematical model that can be used for this purpose is derived from equations for predicting noise-induced permanent threshold shift given in International Standard ISO 1999 combined with the Modified Power Law. The model implies that any noise exposure that would cause deterioration of the hearing threshold levels of a person with normal hearing would also be harmful to the hearing of a person with sensorineural hearing impairment. It follows that, in order to ensure that no deterioration occurs in the hearing of a hearing aid user, the output levels from the aid must be such that they would not cause any damage to a person with normal hearing. This constraint can be met for hearing aid users with mild-to-moderate sensorineural hearing loss but cannot be met for users with severe-to-profound loss because it would result in the provision of insufficient gain, particularly at the higher frequencies. If the model is valid, then for this group, some appropriately small amount of hearing damage must be accepted as the cost of the advantages gained from the use of a hearing aid. Verification of the model is essential before the model is used in clinical practice to determine the risk of deterioration in hearing due to hearing aid use.

Auditory Fatigue