PubMed Health⌕ Search

PubMed · 6821195

Ovulation detection in the human.

Abstract

The importance of predicting human ovulation for either optimizing or avoiding conception has been considered from an endocrine, morphological and clinical view point. Of the biochemical markers in peripheral blood, a knowledge of the LH peak is the most clearly defined, with a two to four fold increase above baseline levels for a relatively short 24-30 hour preovulatory period. Ovulation is considered to occur 28-36 hours after the beginning of the LH rise or 8-20 hours after the LH peak. Daily assessment of the rise in preovular oestrogen reflects Graafian follicle development but the rise is less distinct and spread over 3-4 days with marked day to day fluctuations. LH induces a marked reduction in oestrogen production some 12 hours prior to ovulation and at the same time induces a two to three fold increase in progesterone production above baseline levels. While these changes in themselves are not great enough for day to day discrimination, a knowledge of their reciprocal relationship may be. The preovular rise in FSH is relatively small compared to LH and the radioimmunoassay technique has not generally been refined to be as rapid and reliable. Monitoring the day to day growth of the preovular follicle ultrasonically is both linear and potentially predictable but there is a wide range of its final diameter (17-26 mm) prior to ovulation making prediction inaccurate. With further refinements in ultrasonic resolution, detection of intrafollicular changes of the cumulus oophorus and granulosal cell layer configuration and thickness may give a closer prediction of the time of ovulation. At a clinical level a knowledge of menstrual cycle length in association with body messages which herald ovulation are useful and may forewarn that ovulation in terms of days is approaching. Such markers as preovulation pain, the detection of periovular cervical mucus and the change in physical character and position of the cervix are reliable signs of preovulation for many well motivated and informed women for either promoting or avoiding conception. A knowledge of the basal body temperature is not a prospective guide to ovulation, but once the thermal shift is established in association with loss of periovular mucus symptoms, the fertile period can be considered to have passed. Because we do not have a precise and simple marker of human ovulation, it is necessary that the most suitable marker of pre- or postovulation is chosen for the particular need in a given individual.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Kerin. 1982. Ovulation detection in the human.. https://pubmed.ncbi.nlm.nih.gov/6821195/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗