PubMed HealthSearch

PubMed · 6827368

Accuracy of deconvolution algorithms assessed by simulation studies: concise communication.

Abstract

Deconvolution has been used to correct first-pass radionuclide angiocardiography for the time course of the delivery of radiopharmaceutical into the cardiopulmonary system. The extreme sensitivity of deconvolution to random errors in the data may account for some of the problems encountered in practice. We implemented several deconvolution algorithms that were suitable for use with the unimodal and multimodal superior vena caval and pulmonary curves found in left-to-right shunt quantification. The sensitivity of the algorithms to random errors was assessed using mathematical test problems degraded with pseudorandom noise. An algorithm that constrained the deconvolved pulmonary curve to be expressable as the non-negative sum of a set of lagged normal curves was found to have the smallest maximum error on the curves tested. Comparison with results from a previously published test problem indicated an error reduction of greater than 50% over previously used algorithms. Use of this algorithm may permit more accurate deconvolution of pulmonary time-activity curves and thereby improve shunt quantification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Kuruc, S Treves, J A Parker. 1983. Accuracy of deconvolution algorithms assessed by simulation studies: concise communication.. https://pubmed.ncbi.nlm.nih.gov/6827368/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From antianginal drugs to myocardial cytoprotective agents.

The existing major classes of antianginal drugs improve quality of life in patients with coronary artery disease, but mortality in these patients remains unacceptably high. In order to limit the complications of the disease, it is vital to limit myocyte loss. Potentially, this can be achieved not only by prophylaxis, but also by protection, against ischemia. Any therapy that increases myocardial resistance to ischemia will protect against cell death and prolong the life of the myocyte, and possibly the patient. The mechanisms of cell damage during ischemia, and possible therapeutic interventions, are discussed.

Heart

Successful extrarenal transplantation from non-heart-beating donors.

The current organ shortage has made utilization of organs from less-than-ideal donors more common. Although several transplant centers use kidneys from non-heart-beating donors (NHBDs), there has been reluctance to extend the use of these donors to extrarenal organs. Of the 130 donors referred to our organ procurement organization between January 1993 and May 1994, 16 (12.3%) were NHBDs. Organ retrieval from 10 of these resulted in extrarenal donation, 5 resulted in renal donation only, and 1 resulted in no retrieval as a result of prolonged warm ischemia (> 2 hr). A total of 39 organs were transplanted from these NHBDs. A rapid en bloc retrieval technique was used for extrarenal NHBDs. The mean warm ischemic time was 15.4 min; preservation times were similar for both NHBDs and heart-beating donors. After liver transplantation (n = 5), one episode of primary nonfunction that was technical in origin required retransplantation. Following simultaneous pancreas-kidney transplantation (n = 6), all patients were insulin independent and free of graft pancreatitis; one patient required hemodialysis (16.7%). After isolated renal transplantation (n = 21), 3 patients (14.3%) required hemodialysis. Three of 4 liver recipients are alive after a mean follow-up period of 12.7 months; all simultaneous pancreas-kidney and renal transplant recipients are alive after a mean follow-up period of 8.4 and 8.3 months, respectively. Three liver allografts, 5 pancreas and kidney allografts, and 19 renal allografts are functioning. The lung allograft was lost to rejection 81 days after transplantation; however, the recipient is alive 3 months after retransplantation. Our results demonstrate that in controlled situations, extrarenal organs can be utilized from NHBDs and can be expected to function similarly to organs retrieved from heart-beating donors. We increased the number of transplanted organs by 8.6% using NHBDs for both renal and extrarenal donation. Continued application of these techniques will likely further increase the number of organs retrieved for transplantation.