Artifacts produced by moving grids.

Abstract

Anti-scatter grids reduce the amount of secondary radiation contributing to the image and improve the signal-to-noise ratio. However, they may also lead to the creation of linear artifacts representing the shadows of the radiopaque septa. Grid motion perpendicular to the septa during the exposure can cause blurring of the artifacts; however, the wider septa of recently proposed grids increase the difficulty of suppressing the artifacts entirely. Physical characteristics which affect perceptibility of grid-line artifacts and the conditions needed for their elimination are analyzed. Sufficient grid movement can eliminate overlap artifacts, while synchronization of linear grid motion with exposure time can suppress artifacts for relatively small grid movements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Bednarek, S Rudin, R Wong. 1983. Artifacts produced by moving grids.. https://doi.org/10.1148/radiology.147.1.6828740

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Longitudinal image deblurring in spiral CT.

PURPOSE: To assess the feasibility of digital deconvolution techniques to improve longitudinal resolution of spiral computed tomography (CT) multiplanar reformations and evaluate how technical factors in deconvolution affect longitudinal resolution, noise, and edge ringing. MATERIALS AND METHODS: Longitudinal line spread function (LSF) of the system was estimated from longitudinal reformations of transaxial spiral CT images of a step test phantom. By using the estimated LSF, longitudinal reformations of the phantom and three clinical spiral CT studies were deconvolved by the methods of Wiener filtering and constrained iterative deconvolution. Edge ringing and image noise were quantified for Wiener filtering and constrained iterative deconvolution. RESULTS: Longitudinal reformations were substantially deblurred and resolution improved after deconvolution. Anatomic boundaries in clinical images were more clearly delineated after restoration. The methods of Wiener deconvolution and constrained iterative deconvolution improved the sharpness of the phantom step boundary at the expense of increased edge ringing and image noise. CONCLUSION: In longitudinal spiral CT reformations, blurring along the longitudinal axis can be reduced by Wiener filtering or constrained iterative deconvolution.

Technology, Radiologic

Re: Film processing.

Explore the source record for details and available documents.

Technology, Radiologic