A simple continuously recording infrared optometer.

Abstract

The design of a continuously recording infrared optometer for measuring dynamic changes in ocular accommodation is described. The optometer operates on the Scheiner principle, provides a good signal-to-noise ratio, and has several practical advantages over other optometers described in vision literature. It is primarily designed for use in animal experimentation but can be used for humans if eye and pupil movements are controlled. The design of a schematic eye for assessing the dynamic response of the optometer is also presented. Several methods of calibrating the optometer in absolute units are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J V Lovasik. 1983. A simple continuously recording infrared optometer.. https://doi.org/10.1097/00006324-198301000-00014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Spatially variant changes in lens power during ocular accommodation in a rhesus monkey eye.

This study investigated the changes in ocular aberrations that occur over the entire lens equatorial diameter during accommodation in iridectomized rhesus monkey eyes to understand the nature of accommodative lenticular deformation. Accommodation was centrally stimulated to a range of different response amplitudes (0 D to approximately 11 D), and ocular aberrations were measured with a Shack-Hartmann wavefront sensor in both eyes of one previously iridectomized 10-year-old rhesus monkey. At the highest amplitude in the two eyes, aberrations were analyzed over entrance pupil diameters ranging from 3 to 8 mm in steps of 1 mm. Root mean square error of the total measured aberrations, excluding defocus, increased systematically with increasing accommodation from about 1 to 3.5 microns. Spherical aberration became systematically more negative, and vertical coma increased significantly in magnitude with accommodation. There was a strong accommodative change in power near the center of the lens and little change in power at the periphery. At the highest accommodative state, decreasing the analyzed entrance pupil diameter from 8 to 3 mm considerably reduced the wavefront error. The greater increase in optical power near the central region of the lens, combined with an accommodative pupillary miosis, would serve to maximize accommodative refractive change while maintaining acceptable image quality.

Accommodation, Ocular↗

Compensation of corneal horizontal/vertical astigmatism, lateral coma, and spherical aberration by internal optics of the eye.

Both the anterior surface of the cornea and the internal optics (the posterior cornea, crystalline lens) contribute to the aberration of a wavefront passing through the eye. Artal, Guirao, Berrio, and Williams (2001) reported that the wavefront aberrations produced by the internal optics offset, or compensate for, the aberrations produced by the cornea to reduce ocular wavefront aberrations. We have investigated the wavefront aberrations of the cornea, internal optics, and complete eye on both the population and individual level to determine which aberrations are compensated and probable paths leading to that compensation. The corneal and ocular aberrations of 30 young subjects at relaxed accommodation were measured with the Topcon Wavefront Analyzer, which simultaneously measures refraction, corneal topography (videokeratoscope), and wavefront aberrations (Hartmann-Shack sensor). We found strong evidence for compensation of horizontal/vertical (H/V) astigmatism (Zernike term Z5) lateral coma (Z8) and spherical aberration (Z12). H/V astigmatism compensation is scaled for each individual, suggesting that it is actively determined by a fine-tuning process. Spherical aberration shows no individual compensation, suggesting that is a passive result of genetically determined physiology. Lateral coma shows individually scaled compensation, some of which may be attributable to eccentricity of the fovea.

Accommodation, Ocular↗

A population study on changes in wave aberrations with accommodation.

Wave aberrations were measured with a Shack-Hartmann wavefront sensor (SHWS) in the right eye of a large young adult population when accommodative demands of 0, 3, and 6 D were presented to the tested eye through a Badal system. Three SHWS images were recorded at each accommodative demand and wave aberrations were computed over a 5-mm pupil (through 6th order Zernike polynomials). The accommodative response was calculated from the Zernike defocus over the central 3-mm diameter zone. Among all individual Zernike terms, spherical aberration showed the greatest change with accommodation. The change of spherical aberration was always negative, and was proportional to the change in accommodative response. Coma and astigmatism also changed with accommodation, but the direction of the change was variable. Despite the large inter-subject variability, the population average of the root mean square for all aberrations (excluding defocus) remained constant for accommodative levels up to 3.0 D. Even though aberrations change with accommodation, the magnitude of the aberration change remains less than the magnitude of the uncorrected aberrations, even at high accommodative levels. Therefore, a typical eye will benefit over the entire accommodative range (0-6 D) if aberrations are corrected for distance viewing.

Accommodation, Ocular↗