Automated data processing and radioassays.

Abstract

Radioassays include (1) radioimmunoassays, (2) competitive protein-binding assays based on competition for limited antibody or specific binding protein, (3) immunoradiometric assay, based on competition for excess labeled antibody, and (4) radioreceptor assays. Most mathematical models describing the relationship between labeled ligand binding and unlabeled ligand concentration have been based on the law of mass action or the isotope dilution principle. These models provide useful data reduction programs, but are theoretically unfactory because competitive radioassay usually is not based on classical dilution principles, labeled and unlabeled ligand do not have to be identical, antibodies (or receptors) are frequently heterogenous, equilibrium usually is not reached, and there is probably steric and cooperative influence on binding. An alternative, more flexible mathematical model based on the probability or binding collisions being restricted by the surface area of reactive divalent sites on antibody and on univalent antigen has been derived. Application of these models to automated data reduction allows standard curves to be fitted by a mathematical expression, and unknown values are calculated from binding data. The vitrues and pitfalls are presented of point-to-point data reduction, linear transformations, and curvilinear fitting approaches. A third-order polynomial using the square root of concentration closely approximates the mathematical model based on probability, and in our experience this method provides the most acceptable results with all varieties of radioassays. With this curvilinear system, linear point connection should be used between the zero standard and the beginning of significant dose response, and also towards saturation. The importance is stressed of limiting the range of reported automated assay results to that portion of the standard curve that delivers optimal sensitivity. Published methods for automated data reduction of Scatchard plots for radioreceptor assay are limited by calculation of a single mean K value. The quality of the input data is generally the limiting factor in achieving good precision with automated as it is with manual data reduction. The major advantages of computerized curve fitting include: (1) handling large amounts of data rapidly and without computational error; (2) providing useful quality-control data; (3) indicating within-batch variance of the test results; (4) providing ongoing quality-control charts and between assay variance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Samols, G H Barrows. 1978. Automated data processing and radioassays.. https://doi.org/10.1016/s0001-2998(78)80039-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience.

BACKGROUND AND PURPOSE: In our clinic a QA program for IMRT verification, fully based on dosimetric measurements with electronic portal imaging devices (EPID), has been running for over 3 years. The program includes a pre-treatment dosimetric check of all IMRT fields. During a complete treatment simulation at the linac, a portal dose image (PDI) is acquired with the EPID for each patient field and compared with a predicted PDI. In this paper, the results of this pre-treatment procedure are analysed, and intercepted errors are reported. An automated image analysis procedure is proposed to limit the number of fields that need human intervention in PDI comparison. MATERIALS AND METHODS: Most of our analyses are performed using the gamma index with 3% local dose difference and 3mm distance to agreement as reference values. Scalar parameters are derived from the gamma values to summarize the agreement between measured and predicted 2D PDIs. Areas with all pixels having gamma values larger than one are evaluated, making decisions based on clinically relevant criteria more straightforward. RESULTS: In 270 patients, the pre-treatment checks revealed four clinically relevant errors. Calculation of statistics for a group of 75 patients showed that the patient-averaged mean gamma value inside the field was 0.43 +/- 0.13 (1SD) and only 6.1 +/- 6.8% of pixels had a gamma value larger than one. With the proposed automated image analysis scheme, visual inspection of images can be avoided in 2/3 of the cases. CONCLUSION: EPIDs may be used for high accuracy and high resolution routine verification of IMRT fields to intercept clinically relevant dosimetric errors prior to the start of treatment. For the majority of fields, PDI comparison can fully rely on an automated procedure, avoiding excessive workload.

Electronic Data Processing↗

The emergence of radiofrequency identification tags: applications in surgery.

Radiofrequency identification (RFID) is a wireless method of automatic identification. Currently, RFID tags are emerging into our environment in many aspects of our lives. Applications are being developed in a variety of fields, including health care. Aspects of surgical care will lend themselves to this approach. This technology could provide large amounts of data that not only carry the promise of improving health care, but also may have an impact on personal aspects of our daily lives. Each of us must become familiar with the risks and benefits of RFID use.

Electronic Data Processing↗