Digital vascular imaging: practical aspects.

Abstract

Seventy-five pairs of digital subtraction angiogram images were evaluated for image quality by four independent observers. Each pair of images was derived from two separate injections in the same patient with only a single variable altered between injections, so that patients served as their own controls. The factors studied were contrast material iodine concentration, total volume of contrast material administered per injection, rate of contrast material injection, and catheter position. Observers consistently preferred images obtained following injection of the contrast agent with the higher concentration of iodine, following injection of the greater volume of contrast agent, and with the catheter placed in the superior vena cava rather than the basilic vein. No statistically significant difference in observer preference was found for the other categories studied.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Eskridge, G J Becker, F E Rabe, R W Holden, E C Klatte. 1983. Digital vascular imaging: practical aspects.. https://doi.org/10.1148/radiology.148.3.6878689

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Treatment of symptomatic carotid stenosis].

Published results and experience at the University Hospital of Zurich clearly indicate that in patients with severe, symptomatic carotid artery stenosis the benefits of carotid endarterectomy clearly outweigh the risks. Surgical treatment also favorably influences outcome in cases with contralateral carotid artery occlusion.

Angiography

Responses of systemic and pulmonary veins to the presence of an intravascular stent in a swine model.

The outcome of stent implantation for children with pulmonary venous obstruction has been characterized by late reocclusion associated with a marked vessel neointimal proliferation. The purpose of this study was to compare the responses of the systemic vein and pulmonary vein to the presence of an intravascular stent, using a Yorkshire swine (N = 10) model. Under cardiopulmonary bypass, a single Palmaz stent was placed in the inferior vena cava (IVC) and right lower pulmonary vein (PV) with sacrifice at 4.9-6.1 months. Angiography and hemodynamic data were determined at 1 and 3 months post-stent implant and prior to euthanasia. All stents were found to be patent, with no difference in degree of thrombosis or neointimal formation. No statistical difference was found in the initial and final stent diameter for both inferior vena cava and pulmonary vein stents (PV initial 6.8 +/- 0.9; final 7.1 +/- 0.6) (IVC initial 10.4 +/- 1.2; final 10.4 +/- 1.2). Electron microscopy demonstrated smooth endothelialization of both pulmonary and systemic venous stent devices. No thrombosis was found on gross morphology. The data indicate that there is no intrinsic difference in the response of the pulmonary vein to the presence of a stent device. The clinical experience of restenosis following stent implantation for pulmonary vein stenosis appears to be more related to variables of final stent diameter combined with the marked intrinsic abnormal vessel architecture, as seen with this condition.

Angiography

Experimental fetal tracheal ligation and congenital diaphragmatic hernia: a pulmonary vascular morphometric analysis.

The authors have previously shown that fetal tracheal ligation (TL) reverses the pulmonary hypoplasia in experimental diaphragmatic hernia (DH) by accelerating fetal alveolar growth. The purpose of this study was to determine if growth of the accompanying macroscopic and microscopic pulmonary vasculature is also accelerated. Eighteen fetal lambs were divided into three experimental groups: diaphragmatic hernia (DH), DH and simultaneous tracheal ligation (DH/TL), and sham-operated controls (C). Animals were delivered near term, the lungs retrieved, and pulmonary capillary growth (5 to 50 microns in diameter) evaluated by standard morphometric techniques. Capillary ultrastructure was evaluated by electron microscopy. Nine additional fetal lambs of the same gestational age were equally divided into the same three groups and their lungs analyzed by pulmonary arteriography for evaluation of large vessel growth (< 100-microns diameter). Computer digital analysis of angiogram lung slices showed that the total area of large vessels was increased in DH/TL lungs when compared with DH lungs and decreased in DH lungs when compared with C lungs (P = .003); however, the ratio of large vessel area per unit of lung area was similar in all groups. Microscopic morphometry of the capillary bed showed that the total number of capillaries was increased in DH/TL lungs over both DH and C lungs (P = .0001); however, the number of capillaries per alveolus (cap/alv) was similar in all groups. In DH/TL lungs, electron microscopy showed normal capillary wall structure and normal thickness of the capillary-alveolar interface, whereas in DH lungs, capillary structure was abnormal and the capillary-alveolar interface was thickened.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography