PubMed Health⌕ Search

PubMed · 6884841

Modified Parkes tenodesis in claw hand.

Abstract

The purpose of this report is to present observations on a modified Parkes tenodesis operation for correction of paralytic claw fingers. The long-term results were evaluated in eight adult patients with an observation time of two to six years. As compared to the findings four months after the operation, the results had not deteriorated with time and were found to be good in six patients and fair in two patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Reikerås, O Histøl. 1983. Modified Parkes tenodesis in claw hand.. https://doi.org/10.1016/s0072-968x(83)80003-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Initial visual information determines endpoint precision for rapid pointing.

We investigated how visual noise in the initial estimate of target location affects precision for rapid pointing. Visual localization thresholds (an error measure) rise systematically with eccentricity, doubling at eccentricities of a degree or less. Previous work, which we confirmed, has shown that the precision of pointing, measured by the standard deviation, to a single isolated target is relatively constant over small lateral extents near the midline, and that pointing error is substantially larger than visual error. We used target uncertainty (randomly chosen locations) to greatly increase visual noise so that we could explore the influence of visual noise on pointing error. We compared precision for comparable visual and pointing tasks as a function of target eccentricity. The target was presented for 110 ms at one of eight isoeccentric locations, chosen at random. Under these conditions, pointing error increased significantly with increasing target eccentricity. Beyond 4 degrees eccentricity, visual thresholds and pointing error were identical. Even when the target remained visible until the movement was completed, initial target eccentricity affected pointing error. The quality of visual information varies with task demands, and therefore so does its influence on endpoint precision. Our results demonstrate that the initial visual information about target location can limit endpoint precision, even over as small a range as 12 degrees in the central visual field (a lateral extent of +/-8.5 cm at the midline).

Fingers↗

[Catch fingertip support in microsurgery to reduce the tremor].

INTRODUCTION: With microsurgical operations one of the main risk factors is physiological tremor. To reduce it, microsurgeons usually fix their forearms and hands up to the fingertips IV-V. on supporting desks (armrests), and on the bone (skull) and skin being operated on. AIM: To improve further microsurgical technique which reduce the tremor. METHODS: The new technique gives microsurgeons support for fingertips I. II. and III. due to the "Bethlehem bridge" that can be placed quite close to the site of operation. RESULTS: An approximately tenfold reduction of tremor can be achieved due to the fixation of the crucial I. II. and III. fingertips, which hold the operating instruments. CONCLUSION: The microsurgical operations could be performed at higher precision level.

Fingers↗