PubMed Health⌕ Search

PubMed · 6908337

[Allergy].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D J Maans. 1980-12-16. [Allergy].. https://pubmed.ncbi.nlm.nih.gov/6908337/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Continuous-flow, on-line monitoring of biospecific interactions using electrospray mass spectrometry.

A continuous-flow analytical screening system is presented using electrospray mass spectrometry to measure the interaction of biologically active compounds with soluble affinity proteins. The biochemical detection system is based on a solution-phase, homogeneous assay. In a first step, compounds to be screened (e.g., biotinylated compounds, concentration range 10-1,000 nmol/L) are injected into a continuous-flow reaction system and allowed to react with the affinity protein (e.g., streptavidin, concentration range 3-48 nmol/L). Subsequently, a reporter ligand (fluorescein-labeled biotin 96 nmol/L) is added to saturate the remaining free binding sites of the affinity protein and the concentration of unbound reporter ligand is measured using electrospray MS in the selectedion monitoring mode. The presence of active compounds in the sample results in an increase of the concentration of unbound reporter ligands. The feasibility of a homogeneous MS-based biochemical assay is demonstrated using streptavidin/biotin and anti-digoxigenin/digoxin as model systems. Compared to radioactive or fluorescence-based biochemical assays, the present assay format does not require the synthesis and purification of labels. Various analytical conditions were investigated to determine the ability of MS to measure the biochemical interactions. The availability of a single ligand that can be detected at 10-50 nmol/L concentrations by electrospray MS is sufficient to set up the biochemical assay. For the biospecific interactions studies, detection limits of 10-100 nmol/L were obtained.

Antigen-Antibody Reactions↗

Challenges to the development of antigen-specific breast cancer vaccines.

Continued progress in the development of antigen-specific breast cancer vaccines depends on the identification of appropriate target antigens, the establishment of effective immunization strategies, and the ability to circumvent immune escape mechanisms. Methods such as T cell epitope cloning and serological expression cloning (SEREX) have led to the identification of a number target antigens expressed in breast cancer. Improved immunization strategies, such as using dendritic cells to present tumor-associated antigens to T lymphocytes, have been shown to induce antigen-specific T cell responses in vivo and, in some cases, objective clinical responses. An outcome of successful tumor immunity is the evolution of antigen-loss tumor variants. The development of a polyvalent breast cancer vaccine, directed against a panel of tumor-associated antigens, may counteract this form of immune escape.

Antigen-Antibody Reactions↗

Liposomes labeled with biotin and horseradish peroxidase: a probe for the enhanced amplification of antigen--antibody or oligonucleotide--DNA sensing processes by the precipitation of an insoluble product on electrodes.

Liposomes labeled with biotin and the enzyme horseradish peroxidase (HRP) are used as a probe to amplify the sensing of antigen-antibody interactions or oligonucleotide-DNA binding. The HRP-biocatalyzed oxidation of 4-chloro-1-naphthol (1) in the presence of H2O2, and the precipitation of the insoluble product 2 on electrode supports, are used as an amplification route for the sensing processes. The anti-dinitrophenyl antibody (DNP-Ab) is sensed by a dinitrophenyl-L-cysteine antigen monolayer associated with an Au electrode. A biotinylated anti-IgG-antibody (Fc-specific) is linked to the antigen-DNP-Ab complex, and the biotin-labeled HRP-liposomes associate with the assembly through an avidin bridge. The biocatalyzed precipitation of 2 on the electrode increases the electron-transfer resistances at the electrode-solution interface or the electrode resistance itself. The binding events of the different proteins on the electrode and the biocatalyzed precipitation of 2 on the conductive support are followed by Faradaic impedance spectroscopy or constant-current chronopotentiometry. DNP-Ab concentrations as low as 1 x 10(-11) g x mL(-1) can be detected by this method. The labeled liposomes were also used for the amplified detection of DNA 3. The oligonucleotide 4, complementary to a part of the target DNA 3 that is a model nucleic acid sequence for the Tay-Sachs genetic disorder, is assembled on an Au electrode. Hybridization of the analyte 3 followed by the association of the biotin-tagged oligonucleotide 5 yields a three-component double-stranded assembly. Sensing of the analyte 3 is amplified by the association of avidin, the labeled liposomes, and the subsequent biocatalyzed precipitation of 2 on the electrodes. The DNA 3 is detected with a sensitivity that corresponds to 6.5 x 10(-13) M. Faradaic impedance spectroscopy and chronopotentiometry were employed to follow the stepwise assembly of the systems and the electronic transduction of the detection of the analyte DNA 3.

Antigen-Antibody Reactions↗