PubMed HealthSearch

PubMed · 6929249

Myelogenous leukemia: current practice.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Ogada. 1980. Myelogenous leukemia: current practice.. https://pubmed.ncbi.nlm.nih.gov/6929249/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Validation of a high-performance liquid chromatographic assay method for pharmacokinetic evaluation of busulfan.

The development and validation of a high-performance liquid chromatographic (HPLC) assay for determination of busulfan concentrations in human plasma for pharmacokinetic studies is described. Plasma samples containing busulfan and 1,6-bis(methanesulfonyloxy)hexane, and internal standard, were prepared by derivatization with sodium diethyldithiocarbamate (DDTC) followed by addition of methanol and extraction with ethyl acetate. The extract was dried under nitrogen and the samples reconstituted with 100 microl of methanol prior to HPLC determination. Chromatography was accomplished using a Waters NovaPak octadecylsilyl (ODS) (150 x 3.9 mm I.D.) analytical column, NovaPak ODS guard column, and mobile phase of methanol-water (80:20, v/v) at a flow-rate of 0.8 ml/min with UV detection at 251 nm. The limit of detection was 0.0200 microg/ml (signal-to-noise ratio of 6) with a limit of quantitation (LOQ) of 0.0600 microg/ml for busulfan in plasma. Calibration curves were linear from 0.0600 to 3.00 microg/ml in plasma (500 microl) using a 1/y weighting scheme. Precision of the assay, as represented by C.V. of the observed peak area ratio values, ranged from 4.41 to 13.5% (13.5% at LOQ). No day-to-day variability was observed in predicted concentration values and the bias was low for all concentrations evaluated (bias: 0 to 4.76%; LOQ: 2.91%). The mean derivatization and extraction yield observed for busulfan in plasma at 0.200, 1.20 and 2.00 microg/ml was 98.5% (range 93.4 to 107%). Plasma samples containing potential busulfan metabolites and co-administered drugs, which may be present in clinical samples, provided no response indicating this assay procedure is selective for busulfan. This method was used to analyze plasma concentrations following administration of a 1 mg/kg oral busulfan dose.

Busulfan

Measurement of plasma busulfan concentration by high-performance liquid chromatography with ultraviolet detection.

Busulfan is widely used in bone marrow transplantation. Increased area under the plasma concentration curve has been shown to correlate with venoocclusive disease, which occurs in approximately 20% of these patients. The authors developed a high performance liquid chromatography assay for the determination of plasma busulfan concentration using ultraviolet detection and a single-step derivatization and extraction. The absolute retention times of busulfan and the internal standard were 2.8 and 5.6 min, respectively. The assay possessed linearity up to 200 mumol/l, sensitivity to at least 0.2 mumol/l, average recovery of 101%, and run-to-run precision (n = 34) of < 7%. Furthermore, the assay proved to be free of interference from 59 medications and correlated highly with a validated method employing gas chromatography with electron capture detection (slope = 0.90, intercept = 0.17, r = 0.98, n = 31). The authors conclude that the method described here is ideally suited for the therapeutic monitoring of busulfan.

Busulfan

HPLC and GLC determination of residual solvents in busulphan.

Quantitative methods using HPLC and GLC for the determination of residual pyridine and ethanol in busulphan have been developed. The measurement errors for pyridine and ethanol in busulphan samples (p = 0.95) were found to be 10% and 7%. It was shown that one recrystallization enabled pure busulphan to be prepared.

Busulfan