PubMed HealthSearch

PubMed · 6939681

Thyroid collars recommended for X-rays.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Tweedle. 1980. Thyroid collars recommended for X-rays.. https://pubmed.ncbi.nlm.nih.gov/6939681/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Shielding performance and clinical applicability of lead-free materials in computed tomography.

Owing to the high radiation exposure associated with computed tomography (CT) examinations and the image quality degradation caused by conventional radiation shielding materials, this study evaluated the dose reduction performance and image quality maintenance potential of a newly developed lead-free composite shielding material. This material was composed of bismuth, tungsten, tungsten carbide, aluminium, and polyurethane. Phantom-based dose measurements demonstrated that the shielding material achieved dose reduction rates ranging from 17.6% to 37.6%, depending on tube voltage. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and changes in tube current-time product (mAs) under a scout-based automatic exposure control (AEC) protocol were analysed according to the presence or absence of the shielding material across regions. For the clinical evaluation, CT scans were performed on four patients. Furthermore, the images were reviewed to evaluate whether this material affected image quality. The shielding material exhibited radiation reduction levels comparable to those reported in previous studies. SNR and CNR analyses showed minor statistical variations in certain regions; however, most differences were not statistically significant, and even significant differences remained within a range that did not compromise diagnostic image quality. Under the scout-based AEC protocol, the use of the shielding material resulted in less than 1% variation in mAs values. No visually perceptible artefacts or clinically significant image quality degradation were observed. The proposed composite shielding material demonstrated the potential to mitigate some limitations of conventional shielding materials and showed preliminary clinical feasibility as an adjunctive strategy for radiation dose reduction in CT examinations.

Radiation Protection

Dosimetric properties of megavoltage grid therapy.

PURPOSE: Grid therapy is a technique used to deliver a high dose of radiation (15-20 Gy) in a single fraction to many small volumes within a large treatment field. This treatment modality is used for the palliative treatment of large, deeply seated tumors, which have either been treated to tolerance with conventional radiation, or, due to massive tumor bulk, would most likely not benefit from a conventional course of radiation therapy. As the dose distribution from megavoltage grid therapy differs significantly from that of conventional radiation therapy (i.e., many large dose gradients exist within the tumor volume), we have measured various dosimetric properties inherent in this unique treatment modality. METHODS AND MATERIALS: The grid is a 16 x 16 array of 1-cm diameter holes in a 7-cm thick piece of custom blocking material. The ratio of shielded to open surface area is 1:1. Depth dose, valley-to-peak ratios, and output factors for this square array grid were measured in a water phantom for several field sizes, as well as for a 1-cm diameter narrow beam using 6 MV and 25 MV photon beams. RESULTS: The depth dose curves for the grid fields lie between those for an open portal and a narrow beam. For the 6-MV beam at dmax, the ratios of the doses delivered to the center of the shielded regions to that under the center of the holes, expressed as valley-to-peak ratios, range from 15 to 40%. At 10 cm, the ratios increase to between 25 and 45%. At 25 MV at both dmax and 10 cm, the valley-to-peak ratios are between 40 and 60%. The output factors, 0.89 for 6 MV and 0.77 for 25 MV, do not depend on field size. CONCLUSION: Megavoltage grid therapy is a unique treatment modality where the dose is delivered differentially to a large volume in one fraction. Characterization of the dosimetric properties has allowed clinical implementation of the grid.

Radiation Protection

Summary statements from the Third Conference on Radiation Protection and Dosimetry.

The Third Conference on Radiation Protection and Dosimetry was conducted in Orlando, FL, on 21-24 October 1991. At the end of the conference, each member of the Technical Program Committee summarized the events considered to be of particular importance. Subjects discussed included dosimetry accreditation programs, regulations, standards, compliance, advances in dosimeters and instrumentation, training, needs in metrology, and funding of dosimetry research. These statements have been collected and combined and are presented as a brief summary of the conference.

Radiation Protection