PubMed Health⌕ Search

PubMed · 6971301

Quantitation in positron emission computed tomography: 3 Effect of sampling.

Abstract

Effect of insufficient transverse sampling on quantitative positron emission computed tomography (ECT) was investigated with computer simulation and measurements on parallel bar and line source phantoms. Aliasing artifacts were observed and were found to be dependent on both the configuration and the location of imaged objects. Images of parallel bar phantoms were found to have aliasing artifacts similar in characteristics to aliasing on one-dimensional signals. In line source images, aliasing effects were manifested as variations in amplitude and full width at half maximum resolution (FWHM) for sources at even slightly different locations in the field of view. It was found that employing sampling distances smaller than one-third of the intrinsic detector FWHM eliminated noticeable aliasing artifacts. Image resolution was also found to be affected by the sampling distance. For a sampling distance equal to one-half of the intrinsic detector FWHM, the imaging FWHM is about 10% worse than the intrinsic FWHM. Selection of sampling distance in noisy environments is discussed. Parallel bar phantoms are shown to have advantages over line sources in the evaluation of sampling and resolution performance of ECT scanners.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Huang, E J Hoffman, M E Phelps, D E Kuhl. 1980. Quantitation in positron emission computed tomography: 3 Effect of sampling.. https://doi.org/10.1097/00004728-198012000-00014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prevalence-dependent diagnostic accuracy measures.

We study prevalence-dependent diagnostic accuracy measures, specifically, positive and negative predictive values. These measures permit an assessment of the clinical utility of diagnostic tests across populations with different disease prevalences. In many cases, prevalence may not be known with certainty and the evaluation of the diagnostic tests must account for this uncertainty. A sensitivity analysis may be desired across a prevalence continuum defining low to high-risk populations. For this scenario, simultaneous inference about the predictive values across a range of prevalences is proposed. For situations where a non-point prior distribution on prevalence is specified, we suggest inferences based on averaging the accuracy measures with respect to the prior, leading to simple numerical summaries. The methods are illustrated in a meta-analysis of diagnostic tests for intravascular device-related bloodstream infection, where the prevalence may vary widely both within and across populations.

Diagnostic Errors↗

Measuring the psychosocial consequences of screening.

The last three decades have seen a dramatic rise in the implementation of screening programmes for cancer in industrialised countries. However, in contrast to screening for infectious diseases, most cancer screening programmes only have the potential to reduce mortality; they cannot lower the incidence of cancer in a population. In fact, most cancer screening programmes have been shown to increase the incidence of the disease as a consequence of over-diagnosis. A further dilemma of cancer screening programmes is that they do not distinguish between healthy people and those with disease. Rather, they identify a continuum of disease severity. Consequently, many healthy people who have abnormal screening tests are wrongly diagnosed. Indeed, studies have demonstrated that for each screening-prevented death from cancer, at least 200 false-positive results are given. Therefore, screening has the potential to be harmful as well as beneficial. The psychosocial consequences of false-positive screening results cannot be determined by diagnostic tests or by other technical means. Instead, patient reported outcome measures must be employed. To measure the outcomes of screening accurately and comprehensively patient reported outcome measures have to capture; the nature and extent of the psychosocial consequences and how these change over time. The outcome measures used must have high content validity and their psychometric properties should be determined prior to their use in the specific population. In particular it is important to establish unidimensionality, additivity and item ordering through the application of Item Response Theory.

Diagnostic Errors↗

Usefulness of diffusion-weighted MRI in human herpesvirus-6 encephalitis.

UNLABELLED: We report a patient with human herpesvirus-6 (HHV-6) encephalitis diagnosed by diffusion-weighted magnetic resonance imaging (DW-MRI). A previously healthy 10-month-old girl developed acute encephalopathy. HHV-6 DNA was detected in her cerebrospinal fluid during the acute phase of the disease by polymerase chain reaction. The patient demonstrated cortical diffusion abnormalities in affected brain parenchyma, partially as the initial or most sensitive sign of encephalitis that could be detected not by conventional MRI but by DW-MRI. Serial imaging showed that the diffusion abnormality DW-MRI returned to normal after 45 days. CONCLUSION: DW-MRI may be a valuable tool for early detection and diagnosis of HHV-6 encephalitis and is more sensitive than conventional MRI to detect a subtle edematous change in the brain.

Diagnostic Errors↗