PubMed Health⌕ Search

PubMed · 6985101

Autoimmunity and circulating immune complexes in retinal vasculitis.

Abstract

This paper presents the results of a point-prevalence study of circulating autoantibodies and immune complexes in 44 patients with isolated retinal vasculitis (RV alone), 38 patients with retinal vasculitis accompanied by systemic inflammatory disease (RV + SID), and 33 patients with a similar range of systemic inflammatory disease but without eye involvement (SID alone). In isolated retinal vasculitis, antiretinal antibodies, non-retinal antibodies, and circulating immune complexes each showed a prevalence of about 50 per cent, but there was an inverse relationship between marked antiretinal autoimmunity and the occurrence of circulating immune complexes. In SID alone, antiretinal antibodies (ret-AB) were of lower prevalence (about 20 per cent) and occurred only in patients who had circulating immune complexes (CIC). Patients with RV + SID fell into two principal categories: (a) ret-AB with CIC, and (b) ret-AB without CIC. In isolated retinal vasculitis, the occurrence of high levels of retinal autoimmunity in the absence of circulating immune complexes was associated with the more severe retinal disease, while in those RV + SID patients who did not express autoimmunity, the more severe retinal disease was associated with the presence of circulating immune complexes. It is suggested that the formation of circulating autoimmune complexes, possibly of an idiotypic: anti-idiotypic character, may be a 'risk' mechanism for limiting retinal-specific autoimmunity, and that certain patients with severe retinal vasculitis may undercompensate or overcompensate in this way.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Kasp-Grochowska, E Graham, M D Sanders, D C Dumonde, Y Kozak, V van Tuyen, J P Faure. 1981. Autoimmunity and circulating immune complexes in retinal vasculitis.. https://pubmed.ncbi.nlm.nih.gov/6985101/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune complexes suppress IFN-gamma signaling by activation of the FcgammaRI pathway.

Antigen-driven immune responses are modulated by immune complexes (ICs), in part through their ability to inhibit IFN-gamma-dependent MHC Class II expression. We have demonstrated previously that ICs dramatically inhibit IFN-gamma-induced activation of human monocytes through the suppression of the JAK/STAT signaling pathway. In the current study, we further explore the mechanisms by which ICs regulate IFN-gamma activation of human monocytes. Consistent with previous studies in monocytes pretreated with ICs, there was a reduction in steady-state levels of RNA by real-time RT-PCR of the IFN-inducible protein 10 gene as well as the FcgammaRI gene. Pull-down assays confirm that IC pretreatment inhibits IFN-gamma-induced STAT1 phosphorylation without affecting the ability of STAT1 to bind to the STAT1-binding domain of the IFN-gamma receptor. In addition, the inhibitory function of ICs was reduced when cells from the FcR common gamma-chain knockout mice were used, supporting the role of the FcgammaRI in this inhibitory pathway. It is unexpected that ICs also require the phosphatase Src homology-2-containing tyrosine phosphatase 1 (SHP-1) to inhibit IFN-gamma induction, as demonstrated by studies with cells from the SHP-1 knockout (motheaten) mice. These data suggest a mechanism of IC-mediated inhibition of IFN-gamma signaling, which requires the ITAM-containing FcgammaRI, as well as the ITIM-dependent phosphatase SHP-1, ultimately resulting in the suppression of STAT1 phosphorylation.

Antigen-Antibody Complex↗

Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase.

In order to increase the sensitivity of liquid chromatography/mass spectrometry (LC/MS) assays of recombinant proteins for pharmacokinetics studies, we have developed an immuno-mass spectrometry assay for EPI-hNE4, a 6237 Da protein currently developed for respiratory distress syndromes. After immunocapture of the analyte in human plasma with magnetic beads coated with anti-EPI-hNE4 antibodies, the intact protein was eluted and separated in reversed-phase LC and then analysed by tandem mass spectrometry (MS/MS) in selected reaction monitoring (SRM) mode. The problem of analytical interference due to endogenous binding antibodies was addressed by successive steps of acidification and neutralisation before immunocapture. Furthermore, potential variations in the recovery of analyte during sample extraction were compensated for by addition of an internal standard recognised by the antibodies. The precision of the assay remained therefore below 15%. A significant increase in assay sensitivity was achieved since the extraction step allowed sample concentration and removal of matrix components interfering with the electrospray ionisation process. Using 0.4 mL of plasma, a limit of quantification at 0.5 ng/mL (80 pM) was reached, which represents a 10-fold improvement in sensitivity over our previous work using sample precipitation. This technique was able to monitor EPI-hNE4 kinetics in the plasma of human subjects for 36 h after an intravenous administration of 0.125 mg/kg.

Antigen-Antibody Complex↗

Antibody arrays for quantitative immunophenotyping.

Detection of multiple surface antigens expressed on living cell is an important step for cell processing and clinical diagnosis. Here we describe the preparation of antibody arrays that allow parallel detection of multiple surface antigens through affinity binding of living cells. An antibody array was fabricated by photo-assisted patterning of an alkanethiol monolayer formed on a gold-coated glass plate and subsequent immobilization of antibodies specific for cell surface antigens in an array format. We demonstrate here that rapid phenotyping can be performed on the array for both adhesion-dependent and non-dependent cells by direct cell binding assays. The density of bound cells on each antibody spot was in accordance with their contents in an original suspension. This result suggests the feasibility of the array-based method for quantitative assessment of multiple antigen expression. These findings will serve to extend the range of fundamental and clinical applications of antibody arrays.

Antigen-Antibody Complex↗