PubMed HealthSearch

PubMed · 6992520

[Manual techniques for taking imprints].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Colombo. 1980. [Manual techniques for taking imprints].. https://pubmed.ncbi.nlm.nih.gov/6992520/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

CaSO4:Dy and LiF:Mg, Cu, P thermoluminescent dosimeters for environmental monitoring in ambient areas of a nuclear power plant.

This paper describes CaSO4:Dy and LiF:Mg, Cu, P which were used for ambient environmental monitoring before the nuclear power plant operation in Guangdong Daya Bay, China, in 1991. Since LiF:Mg, Cu, P was first used as an environmental dosimeter in this laboratory, the intercomparison of both thermoluminescent dosimeters, including laboratory irradiation and environmental exposure in Beijing reference spots, was conducted in cooperation with National Institute of Metrology and Laboratory of Industrial Hygiene, measured values of both thermoluminescent dosimeters were in agreement with the error being less than +or- 2% for the laboratory irradiation. The results of measurement by both thermoluminescent dosimeters were quite in agreement with environmental reference exposure rates measured by a pressurized ionization chamber. The largest error of CaSO4:Dy environmental monitoring results in Daya Bay also showed that the differences of measurement results between two thermoluminescent dosimeters were not significant. The experiment results indicated that LiF:Mg, Cu, P was a good environmental dosimeter.

Calcium Sulfate

The effect of steam sterilization on the properties of set dental gypsum models.

The aim of this study was to investigate the viability of autoclave sterilization of set dental gypsum models. The effects of autoclaving on the strength, surface hardness and dimensions of specimens of plaster, stone and diestone were investigated. In addition, sodium succinate was used to minimize any changes produced by autoclaving. It has been shown that dental gypsum casts can be successfully steam sterilized. The results showed that for fully-dried gypsum products, autoclaving at 132 degrees C for 5 minutes rendered the casts unacceptable for use. Autoclaving at 121 degrees C for 16 minutes had less effect although casts were still not satisfactory, with the main problems being excessive expansion for plaster and significant strength and surface hardness loss for stone and diestone. The effect of three additional treatment procedures was examined and the least degradation was observed when the casts were soaked in 1 per cent sodium succinate solution and dried prior to autoclaving, then soaked in water immediately after. Using this procedure the average change in properties for plaster, stone and diestone respectively were: loss of strength 36, 21 and 28 per cent, loss of surface hardness 34, 21 and 33 per cent, and linear expansion 0.05, 0.09 and 0.13 per cent. Further refinement may improve the procedure.

Calcium Sulfate

The effect of potential investment expansion and hot strength on the fit of full-crown castings made with a gypsum-bonded investment.

OBJECTIVES: It has been claimed that the strength of the investment mold at the casting temperature affects the dimensional accuracy of castings (e.g., Markley, 1953; Earnshaw, 1957; Asgar, 1972), but the relationship has not been studied quantitatively. In this investigation, the effects of both mold expansion and hot strength on the relative inaccuracy of full-crown castings have been measured and analyzed. The likelihood that a strong investment could cause distortion of the casting by non-uniform restriction of casting shrinkage (Earnshaw, 1969b) was also considered. METHODS: Castings were made with a commercial gypsum-bonded inlay investment, used both as supplied and with modifications that increased its expansion and reduced its hot strength. In both series of tests, the investments were used over a wide range of liquid/powder (L/P) ratios in casting rings fitted with dry ceramic liners, and set under dry conditions. RESULTS: Casting inaccuracy showed a significant linear correlation with total expansion and a highly significant linear correlation with the combination of total expansion and hot strength. The modified investment, with its low hot strength, gave less distortion of casting shape than did the much stronger unmodified material. However, it was found that to ensure sound castings, the hot compressive strength should not be less than 1.8MPa. SIGNIFICANCE: This investigation showed that while investment expansion is the major variable affecting casting inaccuracy, hot strength is an important modifying factor which also has to be considered when predicting casting inaccuracy from measured properties of the investment.

Calcium Sulfate