PubMed HealthSearch

PubMed · 7007856

Flow cytometry.

Abstract

A brief review of flow cytometry is presented. Emphasis is on the construction of relatively simple instruments and on their application to problems in medical physics. Among these are the problems of measuring the biological parameters that determine the response of tumors to therapy and of measuring the biological damage in people exposed to ionizing radiations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Norman. Flow cytometry.. https://doi.org/10.1118/1.594729

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user's guide for avoiding errors in absorbance image cytometry: a review with original experimental observations.

The sources of errors which may occur when cytophotometric analysis is performed with video microscopy using a charged-coupled device (CCD) camera and image analysis are reviewed. The importance of these errors in practice has been tested, and ways of minimizing or avoiding them are described. Many of these sources of error are known from scanning and integrating cytophotometry; they include the use of white instead of monochromatic light, the distribution error, glare, diffraction, shading distortion, and inadequate depth of field. Sources of errors specifically linked with video microscopy or image analysis are highlighted as well; these errors include blooming, limited dynamic range of grey levels, non-linear responses of the camera, contrast transfer, photon noise, dark current, read-out noise, fixed scene noise and spatial calibration. Glare, contrast transfer, fixed scene noise, depth of field and spatial calibration seem to be the most serious sources of errors when measurements are not carried out correctly. We include a table summarizing all the errors discussed in this review and procedures for avoiding them. It can be concluded that if accurate calibration steps are performed and proper guidelines followed, image cytometry can be applied safely for quantifying amounts of chromophore per cell or per unit volume of tissue in sections, even when relatively simple and inexpensive instrumentation is being used.

Cytological Techniques

Levitation, holding, and rotation of cells within traps made by high-frequency fields.

Biological cells and other particles can be electrically manipulated by means of negative dielectrophoresis within microchambers whose electrode geometry is of the order of the cell size. Very-high-frequency fields (50 MHz and above) and media of increased relative permittivity are especially suitable for the purpose, as shown by experimental data on levitation and rotation. It appears to be possible to move and rotate cells or particles at will using this technology.

Cytological Techniques