PubMed Health⌕ Search

PubMed · 7010002

Pulmonary embolism.

Abstract

Acute pulmonary embolism is one of the most serious of the life-threatening illnesses, but it can be prevented or effectively treated. Unfortunately, there are no safe, rapid, or inexpensive tests for its detection, and so a high degree of alertness remains the clinician's best ally in the diagnosis of this disorder. Among the more useful diagnostic measures, a radioisotope ventilation-perfusion lung scan may be done in the search for a mismatch-an area normally ventilated where there is a perfusion defect. If two or more segmental mismatches are found, there is a high probability that pulmonary embolism is present. A normal perfusion scan virtually eliminates the possibility of pulmonary embolism, but an abnormal ventilation-perfusion scan is not synonymous with the diagnosis of pulmonary embolism and may lead to the overdiagnosis of this disorder. Subcutaneous administration of heparin has proved to be an effective measure in preventing deep venous thrombosis, but it must be started before any thrombosis occurs. Intravenous use of heparin and oral anticoagulation are the mainstays of the therapy of deep venous thrombosis and pulmonary embolism.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E C Rosenow, P J Osmundson, M L Brown. 1981. Pulmonary embolism.. https://pubmed.ncbi.nlm.nih.gov/7010002/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Doppler-free/Doppler-sliced ion imaging.

We demonstrate a hybrid Doppler-free/Doppler-sliced ion imaging approach that is well-suited for detection of H or D atoms. The method relies on 2 + 1 resonant ionization with identical, nearly counterpropagating beams that are coplanar but directed at a small angle relative to the detector face. This results in Doppler selection of the velocity component along the time of flight axis but Doppler-free detection in the plane perpendicular to this axis. The results show high signal level and excellent slicing ( approximately 5%), yielding velocity resolution completely determined by cation recoil in the ionization step.

Doppler Effect↗

Detection and correction of aliasing in ultrasonic measurement of blood flows with Ultrasonic-Measurement-Integrated simulation.

Detailed information of real blood flows is essential to develop an accurate diagnosis or treatment for serious circulatory diseases such as aortic aneurysms. Ultrasonic-Measurement-Integrated (UMI) simulation, in which feedback signals from the ultrasonic measurement make the simulation converge to the real blood flow, is a key to solving this problem. However, aliasing in the ultrasonic blood velocity measurement causes UMI simulation to converge to an erroneous result. In this paper, we have investigated the detection and the correction of aliasing in UMI simulation. The artificial force in the feedback of UMI simulation can be used as an index to detect the aliasing. We have proposed two ways for the correction of the aliasing. Correction A, in which measurement velocity is replaced with the computational one at the monitoring point where the aliasing is detected, substantially improves the accuracy of UMI simulation. Correction B, in which measurement velocity is replaced with an estimated Doppler velocity, can provide exactly the same result as that of UMI simulation using the nonaliased standard solution. Although correction B gives the most accurate result, correction A seems more robust and, therefore, a beneficial choice considering the other artifacts in the measurement.

Doppler Effect↗