Differential lung ventilation with a modified ventilator.

Abstract

To achieve synchronized differential pulmonary ventilation, an Ohio 560 ventilator was modified through separation of the outputs of the deep breath bellows and the tidal volume bellows and providing independent volume, flow rate, PEEP, oxygen-humidification, and alarm systems. The described ventilator modification is simple, inexpensive, and does not alter the performance characteristics of the original unmodified ventilator. Differential lung ventilation may be more easily achieved with this modified ventilator than with the simultaneous use of two ventilators or external electronic synchronizers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Popovich, O J Sanders, D Vij, J J Polanski, W A Conway. 1981. Differential lung ventilation with a modified ventilator.. https://doi.org/10.1097/00003246-198106000-00012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of continuous positive airway pressure on forced expiratory flows in infants with tracheomalacia.

Continuous positive airway pressure (CPAP) is used to minimize airway collapse in infants with tracheomalacia. Forced expiratory flows (FEFs) at functional residual capacity (FRC) increase with increasing CPAP in infants with tracheomalacia, and it has been suggested that CPAP prevents airway collapse by "stenting" the airway open. Since FEF is greater at higher than at lower lung volumes, we evaluated whether the increase in flow measured at FRC (V FRC) with CPAP could be explained by the increase in FRC with CPAP. We measured full FEF-volume curves at CPAP levels of 0, 4, and 8 cm H2O in six infants with tracheomalacia and five healthy control infants. In both groups of infants, FVC did not change with CPAP; however, inspiratory capacity (IC) decreased and thus FRC increased with increasing CPAP. FEFs at FRC increased with increasing levels of CPAP; however, the FEFs at 50% and 75% of expired volume were not different for the three levels of CPAP for both groups of infants. Our finding that FEFs measured at the same lung volumes did not differ for the different levels of CPAP indicates that CPAP affects forced flows primarily by increasing lung volume.

Forced Expiratory Flow Rates

Chronic obstructive pulmonary disease and '150 years of blowing'.

Spirometry is now an established and important aspect of investigation of many lung diseases. This article considers the history of spirometry, how we come to use the current indices of dynamic lung function, and the role of spirometry in the management of patients with chronic obstructive pulmonary disease.