Dynamic computed tomography through interpolation.

Abstract

A method is proposed to reduce the requirement on the scanning speed for dynamic computed tomography of relatively fast moving objects such as the heart. From the projections measured at different times, a set of optimal projections is computed for reconstructing the image at any specified time within a permissible interval. In the method, the corresponding characteristic features of the measured projections at the same viewing angle are matched optimally by a nonlinear transformation. The matched projections are then used in an interpolation procedure to compute the projections required at the specified time. The method has been tested with mathematical phantoms that undergo partial expansion, contraction, and translational motion. The results show that the proposed method can provide acceptable images from data collected at scanning speeds that would otherwise produce severely blurred images by conventional methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H C Lee, C H Leung. 1982. Dynamic computed tomography through interpolation.. https://doi.org/10.1097/00004728-198202000-00022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Evaluation and documentation of tomographic images and further data using the Apple-Macintosh PC].

Use of the personal microcomputer for the analysis of clinical cardial PET studies acquired at the Paul Scherrer Institute in Villigen, Switzerland. At present this is the only PET facility in Switzerland. As the local computers were not usually available for image analysis, it was necessary to find a convenient way to visualize and analyze the PET images in our department in the Cantonal Hospital, Aarau (distance to Villigen some 30 km). The personal microcomputer is, as other authors have already shown, in fact capable of handling the acquired images (128 by 128 pixels) easily. We use a Macintosh IIcx (16 MHz Motorola 68030 CPU) as image analysis workstation. In spring 1990 we implemented a software which could read the original Siemens matrix file directly into the Macintosh PC. As the handling of this software was somewhat clumsy, we now use a very powerful software ("Explorer", UCLA), which is specially designed for PET analysis. Analysis of PET data on the personal computer saves both time and money as we are able to use a standard PC periphery, which is less expensive than specially designed medical units.

Heart