PubMed HealthSearch

PubMed · 7073657

[Solid metal plates with double compression effect for functionally stable osteosynthesis].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L N Ankin, S A Spassow. 1982. [Solid metal plates with double compression effect for functionally stable osteosynthesis].. https://pubmed.ncbi.nlm.nih.gov/7073657/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional methods vs rigid internal fixation of mandible fractures.

OBJECTIVE: To compare traditional methods (ie, intermaxillary fixation with interosseous wiring or external fixation) with newer techniques (ie, plating, use of lag screws) of open reduction and fixation of mandible fractures. DESIGN: Retrospective analysis of data from medical records. SETTING: Academic urban medical center. PATIENTS: Nonrandomized sample of 356 patients admitted to the hospital for treatment of mandible fractures from 1987 through 1991; 155 patients treated with open reduction and fixation were studied. INTERVENTIONS: Sixty-nine patients were treated with interosseous wire fixation or external fixation, 86 patients with rigid internal fixation. MAIN OUTCOME MEASURES: Presence of infection, nerve impairment, nonunion, malunion, operative time, and follow-up. RESULTS: No significant difference was noted between the two groups for sex, treating service, delay in presentation, antibiotic coverage, mechanism of injury, or type of fracture. The incidence of infection, nerve injury, and unavailability for follow-up were greater in patients treated by the newer techniques. Overall expense and operative time were greater in the group treated with plates and lag screws. CONCLUSIONS: We advocate traditional techniques for patients with mandible fractures requiring open reduction and fixation.

Bone Plates

Mechanical analysis of maxillofacial miniplates.

The effect of compression and tensile forces on different types of maxillofacial miniplates was measured, in both as supplied and after bending states. Tests showed all plates showed values of tensile force at failure in excess of that found in most clinical situations; twisting through 90 degrees about the long axis had little effect. In flatwise bending tests there was a wide scatter of values of bending stiffness and ultimate load, indicating that some plates may be stronger than necessary. Repeatedly bending the plates reduced their bending stiffness, particularly in the continuous holed plates, and increased their ultimate load to failure. Values of bending stiffness and ultimate load were much larger when bending in the edgewise direction, with large differences between manufacturers. The data generated in the current study may assist the surgeon in deciding which type of plate to select for a particular clinical situation.

Bone Plates