PubMed HealthSearch

PubMed · 7078732

Trajectory determines movement dynamics.

Abstract

The relation between figural and kimematic aspects of movement was studied in handwriting and drawing. It was found that, throughout the movement, the tangential velocity. V is proportional to the radius of curvature r of the trajectory: V= kr, or, equivalently, that the angular velocity is constant: dalpha(t)/dt = K. However, the constant k generally takes several distinct values during the movement, the changes being abrupt. These changes suggest a clear segmentation of the movement into units of action which overlap but do not coincide with the figural units as defined by the discontinuities of the movement (cuspids, points of inflection). This organisational principle holds even when movements are mechanically constrained or are executed under strict visuo-motor guidance. Moreover, the segmentation of a given trajectory is invariant with respect to the total duration of the movement. A tentative interpretation of the principle is proposed which results from the assumption that the actual movement is produced as a continuous approximation to an intended movement, and that the well known relationship between movement speed and extent in rectilinear trajectories (Fitts' law) also applies to such continuous approximation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Viviani, C Terzuolo. 1982. Trajectory determines movement dynamics.. https://doi.org/10.1016/0306-4522(82)90277-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A nanomechanical device based on the B-Z transition of DNA.

The assembly of synthetic, controllable molecular mechanical systems is one of the goals of nanotechnology. Protein-based molecular machines, often driven by an energy source such as ATP, are abundant in biology. It has been shown previously that branched motifs of DNA can provide components for the assembly of nanoscale objects, links and arrays. Here we show that such structures can also provide the basis for dynamic assemblies: switchable molecular machines. We have constructed a supramolecular device consisting of two rigid DNA 'double-crossover' (DX) molecules connected by 4.5 double-helical turns. One domain of each DX molecule is attached to the connecting helix. To effect switchable motion in this assembly, we use the transition between the B and Z forms of DNA. In conditions that favour B-DNA, the two unconnected domains of the DX molecules lie on the same side of the central helix. In Z-DNA-promoting conditions, however, these domains switch to opposite sides of the helix. This relative repositioning is detected by means of fluorescence resonance energy transfer spectroscopy, which measures the relative proximity of two dye molecules attached to the free ends of the DX molecules. The switching event induces atomic displacements of 20-60 A.

Biomechanical Phenomena

Occipital screw pullout strength. A biomechanical investigation of occipital morphology.

STUDY DESIGN: A three-group design with consistent pullout strength measures. OBJECTIVES: To determine pullout strength of three fixation types (unicortical screws, bicortical screws, wires) and to investigate their correlation with respect to occipital morphology. SUMMARY OF BACKGROUND DATA: A secured, multidirectional occipitocervical fusion requires internal fixation. Devices secured at occipital protuberance were suggested to offer the greatest pullout strength because of this region's thickness. METHODS: Twelve fresh human cadaveric occiputs were sketched with a grid delineating 21 fixation sites. Each site was drilled and hand-tapped. Four specimens were instrumented with unicortical screws on one side of the midline and bicortical screws on the other. Another four were instrumented with bicortical screws and wires, and the remaining four were instrumented with unicortical screws and wires. Two points on each specimen were secured with identical fixation to examine side-to-side symmetry. An MTS materials testing apparatus (MTS Systems Corporation, Eden Prairie, MN) was used to displace the fixators. Pullout strengths at different anatomic locations were recorded. RESULTS: The greatest pullout strength was at the occipital protuberance for all fixation types. The bicortical pullout strength was 50% greater than unicortical. The wire pullout strength was not significantly different from that of the unicortical screw (P > 0.05). Seventy-eight percent of wires broke at 1100 N. Unicortical pullout strength at occipital protuberance was comparable with that of the bicortical screw at other locations. CONCLUSIONS: Unicortical screw fixation at occipital protuberance offers acceptable pullout strength without the potential complications of bicortical screws or wire fixation.

Biomechanical Phenomena

The effect of target size and inertial load on the control of rapid aiming movements. A test of speed-sensitive and speed-insensitive strategies.

Two experiments are reported that investigated the effects of target size and inertial load on the control of rapid aiming movements. Based on kinematic profiles, movements were partitioned into their preprogrammed initial impulse- and feedback-based error correction phases. Electromyographic (EMG) rise rates were examined to investigate whether participants used a speed-sensitive or speed-insensitive control strategy. The results from both experiments showed that initial impulse velocity and EMG rise rates varied as a function of target size, i.e., a speed-sensitive strategy. This was the case whether participants were allowed to make error corrections to their movements (experiment 1) or were instructed to produce initial impulses that hit the target (experiment 2). Both experiments also showed that initial impulse velocity and endpoint variability were inversely related to inertial load. The results from experiment 2 indicated that, while the manipulation of inertial load had no effect on EMG rise rates for movements to a large target, EMG slopes were modulated between inertial load conditions when the target was small.

Biomechanical Phenomena