PubMed HealthSearch

PubMed · 7083575

The test-assessment chart.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Keller, U Gessner. 1982. The test-assessment chart.. https://pubmed.ncbi.nlm.nih.gov/7083575/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[A rapid analysis of the lipid profile. A comparative study of different analytical methods for determination of blood lipids].

A simple and rapid analytical assay for determination of total cholesterol, HDL-cholesterol and triglycerides in capillary blood samples has been compared with established laboratory methods in a group of 41 test subjects. The new method produces results that are fully acceptable for determination of these three lipid parameters, and agree well with the results obtained in serum by established laboratory methods. The Cholestech LDX analyser may be useful for providing rapid and accurate measurements of the lipid profile, including total cholesterol, triglycerides and HDL-cholesterol. Its small size, the speed of analysis and the fact that it is easy to use make the Cholestech LDX a suitable instrument for use in out-patient clinics and primary care medicine.

Blood Chemical Analysis

Comparison of micro-enzymatic and high-performance liquid chromatographic methods for the assay of serum 1,5-anhydroglucitol.

Serum 1,5-anhydro-D-glucitol (AG) has been proposed as a marker of glycaemic control in diabetic patients. Two methods have been developed which could be applied to routine clinical monitoring of serum AG. We have compared the assay characteristics of an adapted enzyme assay, based on the enzyme pyranose oxidase, with a high-performance anion-exchange chromatographic method using pulsed amperometric detection (HPAEC-PAD). Linearity and minimum detectable concentrations were practically identical (to at least 400 mumol/l and 4 mumol/l AG, respectively), though intra- and inter-assay precision was better with the HPAEC PAD system at a clinically relevant concentration of 40 mumol/l AG (9.8% vs. 11.8% and 9.2% vs. 13.0%, respectively). The recovery of added AG to serum samples was lower with the micro-enzyme assay than the HPAEC-PAD assay (74 +/- 15% vs. 102 +/- 8%). Despite good agreement by linear regression (r = 0.974, P < 0.005), the assay methods did not demonstrate satisfactory agreement when using a difference plot (limits of agreement -16.1 to 18.7 mumol/l). We conclude that although both assay methods are applicable to routine analyses, the HPAEC-PAD is more precise and is more specific for AG than the enzyme based assay.

Blood Chemical Analysis

Diol-bonded silica gel as a restricted access packing forming a binary-layered phase for direct injection of serum for the determination of drugs.

Direct serum injection for drug determinations can be achieved on a diol-bonded silica gel as a restricted access packing. The diol-bonded phase, 3-(2,3-dihydroxypropoxy)propylsilylsilica, contains two different functions, a hydrophilic function at the tip of the single chemical bond and a hydrophobic function on the inside part of the bond to form a "binary-layered phase" on the support surface. Proteins, as large molecules, contact only the hydrophilic surface of the diol phase, and they are eluted at the solvent front based on size-exclusion chromatography. On the other hand, small molecules such as synthetic drugs are retained on the internal hydrophobic function and separate based on reversed-phase chromatography. Accordingly, the diol-bonded silica gel performs as a restricted access packing for direct serum injection for the determination of relatively hydrophobic drugs.

Blood Chemical Analysis