Automatic dew-point temperature sensor.

Abstract

A device is described for measuring dew-point temperature and water vapor pressure in small confined areas. The method is based on the deposition of water on a cooled surface when at dew-point temperature. A small Peltier module lowers the temperature of two electrically conductive plates. At dew point the insulating gap separating the plates becomes conductive as water vapor condenses. Sensors based on this principle can be made small and rugged and can be used for measuring directly the local water vapor pressure. They may be installed within a conventional ventilated sweat capsule used for measuring water vapor loss from the skin surface. A novel application is the measurement of the water vapor pressure gradients across layers of clothing worn by an exercising subject.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Graichen, R Rascati, R R Gonzalez. 1982. Automatic dew-point temperature sensor.. https://doi.org/10.1152/jappl.1982.52.6.1658

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Human sclera: thickness and surface area.

PURPOSE: To assess the mean thickness and surface area of human sclera. METHODS: Fifty-five formalin-fixed eye bank eyes were hemisected from anterior to posterior. Cross-sectional slides were taken to include a millimeter scale ruler in each photograph. Slide photographs were projected and the scleral silhouette sketched. Mean scleral thickness measurements with standard deviation were obtained. Twenty-five human eye bank eyes were used to determine total scleral surface area by either a computerized tracing method (17 globes) or volumetric calculations (eight globes) using fluid displacement. RESULTS: Mean scleral thickness +/- SD was 0.53 +/- 0.14 mm at the corneoscleral limbus, significantly decreasing to 0.39 +/- 0.17 mm near the equator, and increasing to 0.9 to 1.0 mm near the optic nerve. The mean total scleral surface area by surface area computerized tracings was 16.3 +/- 1.8 cm2 and, by the volume displacement method, was 17.0 +/- 1.5 cm2. CONCLUSIONS: Scleral thickness and surface area measurements from cadaver eyes are important for ophthalmic surgeons and have implications for transscleral diffusion.

Body Surface Area

Lognormal distributions for skin area as a function of body weight.

This paper reanalyzes the dataset cited by the U.S. Environmental Protection Agency in its Exposure Factors Handbook that contains measurements of skin area, height, and body weight for 401 people spanning all stages of development. The reanalysis shows that a univariate model for total skin area as a function of body weight gives useful and practical results with little or no loss of reliability as compared to the Agency's bivariate model. This new result leads to a new method to develop Lognormal distributions for total skin area as a function of body weight alone.

Body Surface Area

A technique for recording and analysis of postural changes associated with thermal comfort.

The recording of posture has a long history in the study of ergonomics, but has generally been concerned with the assessment of mechanical strain on the human body. This paper extends the concern to the thermal implications of posture. A change in posture can change the effective body surface area available for heat exchange with the environment and therefore the metabolic rate per unit body surface area. This effect is systematised into a method of postural coding which reflects the extent of changes in effective body surface area available for heat exchange. The paper reports a brief assessment of the extent of the effect of posture in normal office work and the extent to which posture is temperature-related.

Body Surface Area