PubMed Health⌕ Search

PubMed · 7122053

Bilateral phakic retinal detachment.

Abstract

Ninety-nine (11.6%) of 850 phakic retinal detachment patients had bilateral detachments. The incidence of bilaterality was greater in nontraumatic detachments (13.4%) than traumatic detachments (3.8%). Patients were divided into two refractive classes: (1) myopic, containing refractive errors of -2.50 diopters or more, and (2) nonmyopic, containing all other refractive errors. The rate of bilaterality in nontraumatic detachments varied with refractive class and lattice degeneration: nonmyopic without lattice (8.1%), nonmyopic with lattice (14.2%), myopic without lattice (16.3%), and myopic with lattice (24.6%). Mean age in years at onset of the initial detachment varied with refractive class and lattice degeneration: nonmyopic without lattice (59.1), nonmyopic with lattice (55.8), myopic without lattice (49.2), and myopic with lattice (28.2). Lattice degeneration reduced the interval between detachments. Annual risks of fellow eye detachments were calculated for four groups: nonmyopic without lattice (0.12%), nonmyopic with lattice (0.95%), myopic without lattice (1.3%), and myopic with lattice (0.98%).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Folk, T C Burton. 1982. Bilateral phakic retinal detachment.. https://doi.org/10.1016/s0161-6420(82)34717-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A comparison of reduction in CT dose through the use of gantry angulations or bismuth shields.

This study investigated the effect of gantry angulation and eye shielding on radiation dose to the eye lens during brain Computed Tomography (CT), and secondly the effectiveness of thyroid and breast bismuth shielding during routine neck and chest CT. An anthropomorphic 'Rando' phantom was scanned at three commonly used gantry angles using this centre's normal adult brain protocol, and for normal adult neck and chest protocols. Bismuth shields were placed over the appropriate organs and dose measured using thermoluminescent dosimeters (TLD). Angling the gantry along the supraorbital meatal plane could reduce the dose by approximately 88% relative to the hard palate and Reid's base line protocols. Bismuth eye shields reduce dose by up to 48% when using either of the first two angles but gave no significant reduction in the supra-orbital plane. Reduction in thyroid dose for neck and chest scans were 55% and 47% respectively, and dose reduction in breast was 23%. We thus conclude that angling the gantry to avoid the orbits is the more effective method of reducing radiation dose to the eyes, with single use bismuth shields to be used where this is not feasible. Thyroid and breast shields should be used where the resultant artefact is not detrimental to image quality.

Eye Injuries↗