PubMed HealthSearch

PubMed · 7162310

Auditory distortion.

Abstract

The auditory system responds to pulsatile energy flow from the environment. Compression and rarefaction of gaseous molecular mass is transduced into electromechanical forms, in order to produce an effect at the cortical level. For energy input to have consistent meaning, transduction must preserve information coded within the pattern of energy flow. Distortion, or alteration of the original form, occurs in many ways throughout the chain of generation/transmission/reception/interpretation. Parameters of energy flow are discussed, and distortion of each parameter is presented in a context which permits the development of a distortion-based analysis of common clinical problems in otolaryngology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Reiter. 1982. Auditory distortion.. https://doi.org/10.1002/lary.1982.92.2.150

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Assay of pancreatic lipase with the surface acoustic wave sensor system.

A new type of surface acoustic wave sensor system for assaying the activity of pancreatic lipase has been proposed. The assay of this enzyme is based on the change in conductance of the solution caused by the release of a fatty acid, using triolein as a substrate. A linear relationship between frequency response and enzyme concentration is obtained. Kinetic parameters of pancreatic lipase, i.e., the Michaelis constant for triolein and the corresponding maximum initial rate, are estimated to be 5.46 mM and 7551.6 Hz/min, respectively. The effects of temperature and pH value are also investigated.

Acoustics

Optimal coating selection for the analysis of organic vapor mixtures with polymer-coated surface acoustic wave sensor arrays.

A method for determining the optimal set of polymer sensor coatings to include in a surface acoustic wave (SAW) sensor array for the analysis of organic vapors is described. The method combines an extended disjoint principal components regression (EDPCR) pattern recognition analysis with Monte Carlo simulations of sensor responses to rank the various possible coating selections and to estimate the ability of the sensor array to identify any set of vapor analytes. A data base consisting of the calibrated responses of 10 polymer-coated SAW sensors to each of six organic solvent vapors from three chemical classes was generated to demonstrate the method. Responses to the individual vapors were linear over the concentration ranges examined, and coatings were stable over several months of operation. Responses to binary mixtures were additive functions of the individual component responses, even for vapors capable of strong hydrogen bonding. The EDPCR-Monte Carlo method was used to select the four-sensor array that provided the least error in identifying the six vapors, whether present individually or in binary mixtures. The predicted rate of vapor identification (87%) was experimentally verified, and the vapor concentrations were estimated within 10% of experimental values in most cases. The majority of errors in identification occurred when an individual vapor could not be differentiated from a mixture of the same vapor with a much lower concentration of a second component. The selection of optimal coating sets for several ternary vapor mixtures is also examined. Results demonstrate the capabilities of polymer-coated SAW sensor arrays for analyzing of solvent vapor mixtures and the advantages of the EDPCR-Monte Carlo method for predicting and optimizing performance.

Acoustics

Simultaneous delivery of electron beam therapy and ultrasound hyperthermia using scanning reflectors: a feasibility study.

PURPOSE: The feasibility of simultaneously delivering external electron beam radiation and superficial hyperthermia using a scanning ultrasound reflector-array system (SURAS) was experimentally investigated and demonstrated. METHODS AND MATERIALS: A new system uses a scanning reflector to distribute the acoustic energy from a planar ultrasound array over the surface of the target volume. External photon/electron beams can be concurrently delivered with hyperthermia by irradiating through the scanning reflectors. That is, this system enables the acoustic waves and the radiation beams to enter the target volume from the same direction. Reflectors were constructed of air-equivalent materials for maximum acoustic reflection and minimum radiation attenuation. Acoustically, the air reflectors were compared to brass reflectors (assumed ideal) for reflectivity and specular quality using several single transducers ranging in frequency from 0.68 to 4.8 MHz. The relative reflectivity was determined from acoustic power measurements using a force-balance technique. The specular quality was assessed by comparing the acoustic pressure fields reflected by air reflectors with those reflected by brass reflectors. Also, acoustic pressure fields generated by a SURAS prototype for two different arrays (2.24 and 4.5 MHz) were measured to investigate field distribution variations as a function of the distance separating the array and the scanning reflector. All pressure fields were measured with a hydrophone in a degassed water tank. Finally, to determine the effect of the air reflectors on electron dose distributions, these were measured using film in a water-equivalent solid phantom after passage of a 20 MeV electron beam through the SURAS. These measurements were performed with the reflector scanning continuously across the electron beam and at rest within the electron beam. RESULTS: The measurements performed using single ultrasound transducers showed that the air reflectors had power reflectivities of 87-96% that of brass, and that for smooth surfaces the reflections from air reflectors were as specular as those from brass reflectors. Acoustic pressure fields measurements of the SURAS for two different arrays showed that the 50% pressure amplitude contours were well-distributed across the projected surface area of the array for different distances separating the array and the reflector. Finally, film dosimetry showed that the electron dose distribution was not affected by the air reflector of the SURAS either for the scanning case or the stationary case. This indicates that the reflectors as made are basically water-equivalent in terms of high energy ionizing radiation. The measured isodoses also indicate that the constructed SURAS prototype would allow the delivery of adequate radiation (90% isodose) to a depth of 2.0 cm. CONCLUSIONS: The results presented show that the SURAS design has the potential to deliver hyperthermia to large superficial tumors, while allowing simultaneous irradiation with 20 MeV electron beams without adverse effects on the radiation dose delivery.

Acoustics