Cerebellar electrical stimulation: a critique.

Abstract

Cerebellar electrical stimulation has been advocated as a beneficial treatment device for improving function in cerebral palsy, but a review of the literature raises questions as to its efficacy and safety. Evaluation of one reported study showed that only 32% of people with implanted cerebellar stimulators had significant improvement in function. This is in contrast to 68% to 92% improvement levels claimed by advocates of the procedure. There is evidence of potential long-term damage to the cerebellum from the device. Further studies are indicated, following the criteria established by the 1976 Medical Device Amendment to the Drug and Cosmetic Act dealing with medical device regulation and control.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A S Bensman, M Szegho. 1978. Cerebellar electrical stimulation: a critique.. https://pubmed.ncbi.nlm.nih.gov/718412/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗