Argon endolaser.

Abstract

We developed an endolaser probe that is capable of delivering argon laser light for photocoagulation of retinal breaks or vascular fronds. Energy is transmitted through a fiberoptic cord from a console outside of the surgical area to an endolaser probe inside the operating suite. The probe can be fired into fluid- or gas-filled media. With the use of this system, panretinal photocoagulation can be performed rapidly and conveniently during a vitrectomy procedure. We have also successfully managed posterior retinal tears and bleeding fibrovascular fronds with this system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Peyman, T C Salzano, J L Green. 1981. Argon endolaser.. https://doi.org/10.1001/archopht.1981.03930020913020

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A direct injection high-efficiency nebulizer for inductively coupled plasma mass spectrometry.

A simple, relatively low-cost direct injection high-efficiency nebulizer (DIHEN) is introduced for argon inductively coupled plasma (Ar ICP) spectrometry. The DIHEN may be operated at solution uptake rates of 1-100 microL/min. Analytical performance indexes for the DIHEN and fundamental characteristics of the aerosol produced are obtained using an ICP mass spectrometer (ICPMS) and a two-dimensional phase Doppler particle analyzer (2D PDPA), respectively. Results are compared to those obtained with a conventional crossflow pneumatic nebulizer (PN), equipped with a Scott-type spray chamber. Droplet sizes and velocities produced with the DIHEN are smaller than those reported for the direct injection nebulizer (DIN). The DIHEN offers optimal sensitivity at low injector gas flow rates (approximately 0.25 L/min) and high rf power (approximately 1.5 kW). For the 17 elements tested, detection limits (ppt) and sensitivities achieved with the DIHEN (at 85 microL/min) are similar to, or better than, those obtained on the same instrument using the PN (at 1 mL/min). However, because the primary aerosol is injected directly into the plasma, oxide-to-metal ion ratios (MO+/M+) are high, as in the case of the DIN. The utility of the DIHEN for the analysis of small-volume samples is demonstrated by microscale flow injection analysis (muFIA) of Cr bound to human lung DNA. Detection of Cr at the femtogram level is feasible.

Argon

Boundary-activated dissociation of peptide ions in a quadrupole ion trap.

Boundary-activated dissociation (BAD) of peptides has been investigated as an alternative to the use of resonant excitation to effect collision-induced dissociation in the quadrupole ion trap. BAD's nonresonant excitation mechanism overcomes a major drawback in resonant excitation, namely, the variation of the resonant excitation frequency as a function of ion space charging. As with resonant excitation, the pulsed introduction of heavy gases (argon, xenon) extends the applicability of BAD when tandem mass spectrometry is performed on peptide ions. The presence of heavy gases during ion activation allows greater internal energy deposition and also enables BAD to be performed at much lower trapping field strengths (lower q values) than previously reported for this technique. This extends the mass range over which product ions can be collected.

Argon

Detectability improvements in capillary zone electrophoresis by combining single capillary isotachophoretic preconcentration and frequency doubled argon ion laser-induced fluorescence detection.

Due to the small path length and low injection volume the concentration limit of detection is comparatively poor in capillary electrophoresis (CZE) with UV detection. This limitation can be overcome by means of preconcentration methods and/or improved detection techniques. This paper describes a strategy where isotachophoresis (ITP) is used to preconcentrate a new cholinesterase inhibitor (NXX-066) prior to a capillary zone electrophoresis analysis in the same single capillary. A hydrodynamic backpressure is used to prevent the analyte from migrating out of the capillary. Laser-induced fluorescence (LIF) is used to further increase the detectability. The total gain in detectability with ITP-CZE-LIF compared to CZE-UV was at least 5500-fold, and it is possible to determine NXX-066 at the 1 nM level. The ITP-CZE method was further evaluated for two beta-blockers; the mean coefficient of variation of the peak areas was 3.4% and the linearity of the calibration plots was satisfying.

Argon